background image

7

1

Visit www.redlion.net for a list of communication drivers and cables.

2

Use this part number to purchase the Crimson

® 

software on CD with a printed manual, USB cable, and RS-232 cable.

Otherwise, download free of charge from www.redlion.net.

3

Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete details.

4

Industrial grade two million write cycles.

ORDERING INFORMATION

LEDS

STS – STATUS LED

The green Status LED provides information regarding the state of the Data

Station. This includes indication of the various stages of the start-up routine
(power-up), and any errors that may occur.

Startup Routine

Rapidly Flashing

INDICATION

Data Station is currently running the boot loader and/or
being flash upgraded by Crimson.

Steady

Data Station is operating properly.

CF – 

C

OMPACT

F

LASH LED

USER COMMUNICATION PORTS - TX/RX LEDS

ETHERNET LEDS

No CompactFlash Card is present.

Off

Incorrectly formatted CompactFlash card present.

Unit is writing to the CompactFlash, either because
it is storing data, or because the PC connected via
the USB port has locked the drive. 

1

Flashing Slowly

Flickering

CompactFlash card is being checked.

Flashing Rapidly

Valid CompactFlash card is present.

Steady

INDICATION

LED

1. Do not turn off power to the unit while this light is flickering. The unit writes

data in two minute intervals. Later Microsoft operating systems will not lock
the drive unless they need to write data; Windows 98 may lock the drive any
time it is mounted, thereby interfering with logging. Refer to “Mounting the
CompactFlash” in the Crimson 2.0 User Manual.

Transmitting

GREEN

Receiving

RED

INDICATION

LED

Note:  LEDs are not available on the Programming Port: RS232/PG.

Link Established

YELLOW (Solid)

100 BASE-TX Communications

AMBER

10 BASE-T Communications

GREEN

Network Activity

YELLOW (Flashing)

INDICATION

LED

DRxxxxxx

DIN Rail Mountable Adapter Products 

3

Accessories

Accessories

Accessories

DR

CBLxxxxx

Communications Cables 

1

CBLUSB00

USB Cable

CBLPROG0

RS-232 Programming Cable

G3CFxxxx

XCRS0000

XCPBDP00

CompactFlash Card 

4

RS232/485 option card for Modular Controller or Data Station Plus

PROFIBUS option card for Modular Controller or Data Station Plus

Data Station Plus

DSP

XCDN0000

XCCN0000

G3CF

XCRS

XCPB

XCDN

XCCN

SFCRM200

PSDRxxxx

Crimson

®

2.0 

2

, Manual and Download Cable

DIN Rail Power Supply

Software

SFCRM2

Power Supply

PSDR

Communications

Cables (10 feet)

CBL

DSPGT000

DSPSX000

DSPLE000

DESCRIPTION

TYPE

Data Station with multiple protocol converter, data logger, web
server with Virtual HMI up to VGA (640 x 480) size and expansion
slot with increased SDRAM.

PART NUMBER

MODEL NO.

Data Station with multiple protocol converter, Comms, Ethernet and
expansion slot.

Data Station with multiple protocol converter, data logger, web
server with Virtual HMI up to QVGA (320 x 240) and expansion slot.

CANopen option card for Modular Controller or Data Station Plus

DeviceNet option card for Modular Controller or Data Station Plus

Summary of Contents for Data Station Plus

Page 1: ...e which can be purchased as part of a kit that includes a manual and cables or downloaded free of charge from www redlion net SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not s...

Page 2: ...s steel Installation Category I Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTING Snaps onto standard DIN style top hat T profile mounting rails according to EN50022 35 x 7 5 and 35 x 15 10 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E302106 UL508 CSA 22 2 No 14 M05 LISTED...

Page 3: ...evices or equivalent are recommended Ferrite Suppression Cores for signal and control cables Fair Rite part number 0443167251 RLC part number FCOR0000 TDK part number ZCAT3035 1330A Steward part number 28B2029 0A0 Line Filters for input power cables Schaffner part number FN610 1 07 RLC part number LFIL0000 Schaffner part number FN670 1 8 07 Corcom part number 1 VR3 Visit RLC s web site at www redl...

Page 4: ...G USB PG RS232 PG ETHERNET WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE NON HAZARDOUS INPUT AND OUTPUT I O WIRING MUST BE IN ACCORDANCE WITH CLASS I DIV 2 WIRING METHODS AND IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION ...

Page 5: ...Bradley equipment PORT 3 ETHERNET CONNECTION RS232 RS485 5 DATA STATION PORT PIN OUTS TROUBLESHOOTING If for any reason you have trouble operating connecting or simply have questions concerning your new Data Station contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion n...

Page 6: ... 0 and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson 2 0 is installed This may have already been accomplished if your Data Station was configured using the USB port Once the driver is installed connect the Data Station to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 0 user manual Note The USB port is for s...

Page 7: ...t lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 0 User Manual Transmitting GREEN Receiving RED INDICATION LED Note LEDs are not available on the Programming Port RS232 PG Link Established YELLOW Solid 100 BASE TX Communications AMBER 10 BASE T Communications GRE...

Page 8: ...uyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those ex...