  CONVERTS NUMEROUS PROTOCOLS SIMULTANEOUSLY

  EXTENSIVE BUILT-IN DRIVER LIST ALLOWS EASY DATA 

MAPPING TO PLCs, PCs, AND SCADA SYSTEMS

  10 BASE-T/100BASE-TX ETHERNET PORT SUPPORTS FOUR 

SIMULTANEOUS PROTOCOLS

  INDEPENDENT SERIAL PORTS PROVIDE VIRTUALLY 

UNLIMITED INTEGRATION METHODS

  SUPPORTS UP TO NINE PROTOCOLS SIMULTANEOUSLY(with 

expansion card)

GENERAL DESCRIPTION

The Data Station Plus was designed to act as a nexus for industrial data 

collection and management. With three built in serial ports and a 10 Base-T/100 

Base-TX Ethernet port, the unit performs protocol conversion, allowing 

disparate devices to communicate seamlessly with one another. The Ethernet 

port supports up to ten protocols simultaneously using Crimson 3, so even 

Ethernet to Ethernet conversion may be performed.

The CompactFlash card allows new configuration files to be loaded into the 

Data Station Plus. The USB port may be used for blazing fast file downloads, or 

to mount the Data Station’s CompactFlash card as an external drive to your PC. 

The Data Station’s DIN rail mounting saves time and panel space and snaps 

easily onto standard top hat (T) profile DIN rail.

SOFTWARE

The Data Station is programmed with Crimson

®

 2.0 software for Windows

® 

 

2000 or later platforms. The software is an easy to use graphical interface which 

can be purchased as part of a kit that includes a manual and cables, or 

downloaded free of charge from www.redlion.net.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other 

actuators not equipped with safeguards. To do so can be potentially harmful to 

persons or equipment in the event of a fault to the controller. An independent 

and redundant temperature limit indicator with alarm outputs is strongly 

recommended.

CompactFlash is a registered trademark of CompactFlash Association.

MODEL DSPLE – DATA STATION PLUS

Bulletin No.  DSPLE-H
Drawing No.  LP0671
Released  04/15

CAUTION: Risk of Danger.

Read complete instructions prior to  

installation and operation of the unit.

5.30 (134.7)

RS232

ETHERNET

CF

STS

USB/PG

RS485

RS232/PG

3.09 (78.5)

4.15 (105.4)

DIMENSIONS  In inches (mm)

FOR USE IN HAZARDOUS LOCATIONS: 

Class I, Division 2, Groups A, B, C, and D

C

US LISTED

UL

R

3PWL

PROGRAMMABLE 

CONTROLLERS

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF 

COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, 

DIVISION 2

THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, 

DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS 

LOCATIONS ONLY

C

US LISTED

UL

R

IND. CONT. EQ.

34AD

Summary of Contents for DSPLE

Page 1: ...h can be purchased as part of a kit that includes a manual and cables or downloaded free of charge from www redlion net SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specifi...

Page 2: ...l 30 g Altitude Up to 2000 meters 7 CONSTRUCTION Case body is burgundy high impact plastic and stainless steel For indoor use only Installation Category II Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTING Snaps onto standard DIN style top hat T profile mounting rails according to ...

Page 3: ...re the unit is mounted b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is over 1 MHz 3 Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heaters etc The cables should be run through metal conduit that is properly grounded This is especially useful in appli...

Page 4: ...S485 USB PG RS232 PG ETHERNET CF STS CBLxxxxx CHASSIS GND OR CBLPROG0 REM SLC 5 03 CPU RUN BATT FLT RUN RS232 DH485 FORCE PROG VDC PWR OUT 24 PWR OUT COM VAC NEUT 120 240 VAC USER POWER POWER RS232 PG USB PG RS232 PG ETHERNET WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE NON HAZARDOUS INPUT AND OUTPUT I O WIRING MUST BE IN ACCORDANCE WITH CLASS I DIV 2...

Page 5: ...of the available cables WARNING Do NOT use a standard DH 485 cable to connect this port to Allen Bradley equipment PORT 3 ETHERNET CONNECTION RS232 RS485 5 EXPANSION 24VDC 10 USB PG TxA PIN 8 GREEN YELLOW LED LED AMBER NIC ETHERNET RS232 PORT COMMS COMMS PORT COMM CTS PIN 1 COMM Rx Tx RTS PIN 6 TxB COMM RxA RxB TxA TxB PIN 1 TxEN RS485 ETHERNET RS232 RS485 CF RS232 PG PORT RTS PIN 6 CTS PIN 1 USB ...

Page 6: ...ls Crimson 2 0 Device after Crimson 2 0 is installed This may have already been accomplished if your Data Station was configured using the USB port Once the driver is installed connect the Data Station to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 0 user manual Note The USB port is for system set up and diagnostics and is not intended for permanent ...

Page 7: ...communication drivers and cables 2 Use this part number to purchase the Crimson software on CD with a printed manual USB cable and RS 232 cable Otherwise download free of charge from www redlion net 3 Antenna G3QANT00 is NOT included with the card Must be purchased separately if needed 4 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 5 Industrial grade two...

Page 8: ...demnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P...

Reviews: