1
CONVERTS NUMEROUS PROTOCOLS SIMULTANEOUSLY
EXTENSIVE BUILT-IN DRIVER LIST ALLOWS EASY DATA
MAPPING TO PLCs, PCs, AND SCADA SYSTEMS
10 BASE-T/100BASE-TX ETHERNET PORT SUPPORTS FOUR
SIMULTANEOUS PROTOCOLS
INDEPENDENT SERIAL PORTS PROVIDE VIRTUALLY
UNLIMITED INTEGRATION METHODS
SUPPORTS UP TO NINE PROTOCOLS SIMULTANEOUSLY(with
expansion card)
GENERAL DESCRIPTION
The Data Station Plus was designed to act as a nexus for industrial data
collection and management. With three built in serial ports and a 10 Base-T/100
Base-TX Ethernet port, the unit performs protocol conversion, allowing
disparate devices to communicate seamlessly with one another. The Ethernet
port supports up to ten protocols simultaneously using Crimson 3, so even
Ethernet to Ethernet conversion may be performed.
The CompactFlash card allows new configuration files to be loaded into the
Data Station Plus. The USB port may be used for blazing fast file downloads, or
to mount the Data Station’s CompactFlash card as an external drive to your PC.
The Data Station’s DIN rail mounting saves time and panel space and snaps
easily onto standard top hat (T) profile DIN rail.
SOFTWARE
The Data Station is programmed with Crimson
®
2.0 software for Windows
®
2000 or later platforms. The software is an easy to use graphical interface which
can be purchased as part of a kit that includes a manual and cables, or
downloaded free of charge from www.redlion.net.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller. An independent
and redundant temperature limit indicator with alarm outputs is strongly
recommended.
CompactFlash is a registered trademark of CompactFlash Association.
MODEL DSPLE – DATA STATION PLUS
Bulletin No. DSPLE-H
Drawing No. LP0671
Released 04/15
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
5.30 (134.7)
RS232
ETHERNET
CF
STS
USB/PG
RS485
RS232/PG
3.09 (78.5)
4.15 (105.4)
DIMENSIONS In inches (mm)
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
C
US LISTED
UL
R
3PWL
PROGRAMMABLE
CONTROLLERS
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,
DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS
LOCATIONS ONLY
C
US LISTED
UL
R
IND. CONT. EQ.
34AD