ET-8xS-MIL_manual r07.doc
Page 4 of 9
Last Revised: 16-Jan-14
Military
Standards
Compliance
MIL Standard
Specification
Description
MIL-STD-810F; 501.4, I;
501.4, II
+70°C Transport/Storage
High Temperature
+65°C operating
MIL-STD-810F; 502.4, I;
501.4, II
-20°C Transport/Storage
Low Temperature
-10°C operation
MIL-STD-810F; 507.4
95%
Humidity
MIL-STD-810F; 500.4, II
9000 Feet
Low pressure operating
MIL-STD-810F; 500.4, I
15000 Feet
Low pressure transportation
MIL-STD-810F; 514
5-1000 Hz
Vibration
MIL-STD-810F; 516, I
half sinus 40g 11msec
Mechanical Shock
MIL-STD-810F; 516, V
Drop on table
Handling Shock
MIL-STD-810F; 509
5% salt for 48 hours
Salt
MIL-STD-810F; 510, I
According to specs
Sand and Dust
MIL-STD-810F, Method 514.5
Vibration while in transport
MIL-STD-810F, Method 512.4
Immersion into water; rain and wind resistance
MIL-STD-1275B
100V for 1 second
15,000 watts peak
250V (50 times for 100uS)
Surge Protection
Transient Voltage
Spike Protection
MIL-STD-461E-RE102
2MHz to 18GHz
Radiated emissions(ground)
MIL-STD-461E-RS103
2MHz to 18GHz
Radiated susceptibility
Safety
Warnings
Strictly abiding by these warnings will help ensure the safe installation, startup and
operation of the switch.
INSTALL THE SWITCH IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL
CODES.
LIGHTNING DANGER: DO NOT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING
ACTIVITY.
WARNING
(EXPLOSION
HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2
(ZONE 2).
WARNING
(EXPLOSION
HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR WIRING
UNITS.
WARNING
(EXPLOSION
HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE
AREA IS KNOWN TO BE NONHAZARDOUS.
Consignes
de Sécurité
Le strict respect de ces avertissements contribuera à assurer la sécurité de l'installation, le
démarrage et le fonctionnement de l'interrupteur.
INSTALLEZ
L’APPAREIL CONFORMÉMENT AUX CODES ÉLECTRIQUES LOCAUX ET
NATIONAUX.
DANGER DE FOUDRE:
NE PAS TRAVAILLER SUR L’ÉQUIPEMENT PENDANT LES PÉRIODES
D’ACTIVITÉS DE FOUDRE.
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE CLASSE I,
DIVISION 2 (ZONE 2).
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON
D’ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER DES MODULES.
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
NE DÉBRANCH
EZ PAS L’ÉQUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU À MOINS
QUE L’ENVIRONNEMENT SOIT CONNU POUR ÊTRE LIBRE DE CONCENTRATIONS
INFLAMMABLES.