background image

GENERAL DESCRIPTION

The G310 Operator Interface Terminal combines unique capabilities normally 

expected from high-end units with a very affordable price. It is built around a 

high performance core with integrated functionality. This core allows the G310 

to perform many of the normal features of the Paradigm range of Operator 

Interfaces while improving and adding new features.

The G310 is able to communicate with many different types of hardware using 

high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100 

Base-TX communications. In addition, the G310 features USB for fast downloads 

of configuration files and access to trending and data logging. A CompactFlash 

socket is provided so that Flash cards can be used to collect your trending and data 

logging information as well as to store larger configuration files.

In addition to accessing and controlling of external resources, the G310 

allows a user to easily view and enter information. Users can enter data through 

the touchscreen or front panel 8-button keypad. 

CONTENTS OF PACKAGE

- G310 Operator Interface.

- Panel Gasket.

- This hardware bulletin.

- Template for panel cutout.

- Hardware packet for mounting unit into panel.

- Terminal block for connecting power.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other 

actuators not equipped with safeguards. To do so can be potentially harmful to 

persons or equipment in the event of a fault to the controller.

ORDERING INFORMATION

MODEL NO.

DESCRIPTION

PART NUMBER

G310

10.4" TFT VGA Display Operator Interface (indoor), 

USB Host, Isolated Comms

G310C210

10.4" TFT VGA Display Operator Interface (indoor), 

Dual Ethernet, USB Host, Isolated Comms

G310C230

10.4" TFT SVGA Display Operator Interface (indoor), 

USB Host, Isolated Comms

G310R210

10.4" TFT SVGA Display Operator Interface (indoor), 

Dual Ethernet, USB Host, Isolated Comms

G310R230

10.4" TFT VGA Display Operator Interface (indoor or 

outdoor), Glossy Finish, USB Host, Isolated Comms 

8

G310S210

10.4" TFT VGA Display Operator Interface (indoor or 

outdoor), Glossy Finish, Dual Ethernet, USB Host, 

Isolated Comms 

8

G310S230

G3CF

CompactFlash Card 

6

G3CFxxxx

G3RS

RS 232/485 Optional Communication Card

G3RS0000

G3CN

CANopen Optional Communication Card

G3CN0000

G3DN

DeviceNet Optional Communication Card

G3DN0000

G3GSM GSM/GPRS Modem Option Card 

3

G3GSM000

G3PBDP Profibus DP Optional Communication Card

G3PBDP00

SFCRM Crimson 

2

SFCRM

CBL

RS-232 Programming Cable

CBLPROG0

USB Cable

CBLUSB00

Communications Cables 

1

CBLxxxxx

DR

DIN Rail Mountable Adapter Products 

4

DRxxxxxx

Replacement Battery 

5

BNL20000

G310C Backlight Replacement 

7

G3BR10C1

G3FILM Protective Films

G3FILM10

1

 Contact your Red Lion distributor or visit our website for complete selection.

2

 Use this part number to purchase Crimson on CD with a printed manual, USB 

cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.

3

 Antenna (G3QANT00) is NOT included with the card. Must be purchased 

separately if needed.

4

 Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete 

details.

5

 Battery type is lithium coin type CR2025

6

 Industrial grade two million write cycles. SMART Modular Technologies model 

SG9CF (UL Listed Directory Category NWGQ).

7

 For use in non-hazardous locations only.

8

 LED backlight is not field replaceable.

MODEL G310C2/R2/S2 - 10.4" COLOR TOUCHSCREEN

Bulletin No.  G310CRS2-D
Drawing No.  LP0809
Released  03/14

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CompactFlash is a registered trademark of CompactFlash Association.

  CONFIGURED USING CRIMSON

®

 SOFTWARE (VERSION 2.0 OR 

LATER)

  UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS  

(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 RS-422/485 

ON OPTIONAL COMMUNICATIONS CARD)

  10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS 

AND HOST WEB PAGES (2

ND 

ETHERNET PORT OPTIONAL)

  USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM A 

PC OR FOR DATA TRANSFERS TO A PC

  UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY 

(32MBYTE FLASH)

  COMPACTFLASH

®

 SOCKET TO INCREASE MEMORY CAPACITY

  10.4-INCH TFT 32K VGA 640X480 PIXEL LCD OR SVGA 800X600 LCD

  OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE

  8-BUTTON KEYPAD FOR ON-SCREEN MENUS

  THREE FRONT PANEL LEDS

  POWER UNIT FROM 24VDC ±20% SUPPLY

  RESISTIVE ANALOG TOUCHSCREEN

CAUTION: Risk Of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

WARNING - EXPLOSION HAZARD - SUBSTITUTION 

OF ANY COMPONENT MAY IMPAIR SUITABILITY 

FOR CLASS I, DIVISION 2

The protective conductor terminal is bonded to conductive 

parts of the equipment for safety purposes and must be 

connected to an external protective earthing system.

1

C

US LISTED

UL

R

43NH

PROCESS CONTROL EQUIPMENT

FOR USE IN HAZARDOUS LOCATIONS: 

Class I, Division 2, Groups A, B, C, and D

Summary of Contents for G310C2

Page 1: ...sh Card 6 G3CFxxxx G3RS RS 232 485 Optional Communication Card G3RS0000 G3CN CANopen Optional Communication Card G3CN0000 G3DN DeviceNet Optional Communication Card G3DN0000 G3GSM GSM GPRS Modem Optio...

Page 2: ...rage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g Shock according to IEC 68 2 27 O...

Page 3: ...face Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wir...

Page 4: ...in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson is installed This may have already been accomplished if your G310 was configured using the USB port Once the driver is...

Page 5: ...1 3 2 4 6 7 ON ON CBLPROG0 ICM5 CONNECTING A G310 OPERATOR INTERFACE TO AN ICM5 Application Dependent ICM5 DIP Switch Settings Examples of RS485 2 Wire Connections G3 to Red Lion RJ11 CBLRLC00 DLC IA...

Page 6: ...his operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell in sensed The touchscreen is fu...

Page 7: ...r in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G310 is a lithium type CR2025 BATTERY INVERTER TOP BOTTOM G310C2 WARNING EXPLOSION HA...

Page 8: ...format CompactFlash Insert Face Up C o m p a c tF l a s h T o p S i d e INDOOR VERSUS OUTDOOR The G310C2x0 and the G310R2x0 use an overlay with a textured finish and keys that are embossed This overla...

Reviews: