Revised 2017-08-31
Services Tab
Drawing No. LP0997-C
RAMQTT Client
Sixnet
®
Series SN/RAM
®
6000 & RAM 9000 Software Manual
- 155 -
Device Root CA:
Root Certificate Authority is required for connecting to AWS. This must be the Root
Certificate Authority provided by AWS.
Note:
You can also click on the file icon to browse to the certificate for use.
Advanced Settings
Port:
Enter the port number associated with the Broker IP address or Domain Name.
The standard ports for MQTT are:
•
Unencrypted: 1883
•
Encrypted: 8883
Keep Alive (seconds):
The Keep Alive value is the maximum time in seconds an idle connection will be
allowed. If no data needs to be transmitted for this period, then an empty Keep Alive packet will be transmitted
to maintain the connection as active with the server. If the Keep Alive is set to 0, it will be disabled. The
acceptable value range is from 1 to 65535.
Caution:
Low values may generate large amounts of unnecessary data.
•
Recommended Setting: The optimal setting is unique to Cloud Service Provider.
Generic: 2 Hours (7200 seconds)
Fusion Connect: Less than 5 Minutes (285 seconds)
Track Server Responses:
If this option is enabled, RAMQTT will receive a response message from the
Broker explaining the status of the message for each message sent. This allows RAMQTT to get more detailed
information on errors that the Broker might report.
Note:
Since each message sent to the Broker will trigger a received message from the Broker, this
will create additional overhead and increase overall data usage.
Allow Incoming Messages:
If set to Yes, RAMQTT will subscribe to topics needed to receive messages from
the Broker. Use this option if RAMQTT should handle incoming messages.
If set to No, RAMQTT will not subscribe to any topics and will not receive any messages from the Broker. Use
this option if RAMQTT should only publish data.
3.5.14.2
AT&T
®
M2X
General
IoT Cloud:
Select the name of the Cloud Service Provider, from the drop down list, that will be receiving
messages from this device.
•
AT&T M2X
Broker:
Enter the Broker IP address or Domain Name provided by the Cloud Service Provider.
Encryption (TLS/SSL):
Select whether the connection will be encrypted.
Registration:
Select whether Auto Registration will be used or if the device is Already Registered.
If Auto Registration is selected enter:
•
Master API Key:
The Master API Key is used to automatically register a device to the cloud. After
device registration is complete, the Device API Key and Device ID will be added to the RAMQTT
configuration and the Master API Key will be removed.
•
Distribution ID:
The Distribution ID is used to tell the cloud that this device is to be auto registered as
part of a Distribution. The Distribution is defined by the user through the cloud side interface.
Note:
If the Distribution ID is provided then the Master API Key must be provided as well.