Advanced Tab
Revised 2017-08-31
GWLNX
Drawing No. LP0997-C
- 244 -
Sixnet
®
Series SN/RAM
®
6000 & RAM 9000 Software Manual
Label (Required):
Enter the Lookup Key associated with this entry. This is commonly a phone number, or a
portion of a phone number for partial matches of incoming calls. (i.e. “18” will match 1-800-xxx-xxx, 1-888,
1-866 and similar numbers.) The recommended setting for this field is 1001.
A value of “default” will designate this entry as the option to use if no other entry matches. If no “default” label
exists, the first entry in the list will be the default and match any incoming number received.
For a Dial/Ring-Out Mode, this field should match the phone number entered in the Com Port Manager
configuration for GWLNX TCP Server port number, if using a dynamic TCP Listening Port.
AT Command Description:
The best choice is often determined by previous testing with a particular model/
brand of connecting device. The first three “Direct” options are the most commonly used. The recommended
setting for this field is Direct 1200 Bell212 = At&Q6+MS=B212
If choosing a User Defined option, enter the full AT command. Below is a list of AT Commands:
•
Direct 1200 Bell212 = AT&Q6+MS=B212
•
Direct 1200 V22 = AT&Q6+MS=V22
•
Direct 2400 V22bis = AT&Q6+MS=V22B
•
Direct2 1200 Bell212 = AT\NO+MS=B212
•
Direct2 1200 V22 = AT\NO+MS=V22
•
Direct2 2400 V22bis = AT\NO+MS=V22B
•
ErrorC 1200 Bell212 = AT\N3+MS=B212
•
ErrorC 1200 V22 = AT\N3+MS=V22
•
ErrorC 2400 V22bis = AT\N3+MS=V22B
Answer/Dial Mode:
For incoming calls, choose “ANSWER_2WAY_RAW”. For outbound (Ring Out/Ring
Down) mode, choose “DIAL”. The other options should only be used if instructed to do so by Red Lion
Technical Support. The recommended setting for this field is ANSWER_2WAY_RAW.
Message Mode:
This will choose between enabling the local VIsa protocol engine or allowing Passthru/
Transparent mode. The recommended setting for this field is Transparent.