background image

2

1" Suction

Hose

Foot Valve

Priming Plug

Street Tee (not 

included)

Garden Hose Adapter

(included)

To Sprinkler System

Garden Hose

Weather Proof Enclosure

To 115 V

Grounded Outlet

Base

To Sprinkler

 System

Handle

To 115 V

Grounded

 Outlet

Base

INSTALLATION

ALTERNATE INSTALLATION AS A BOOSTER PUMP

Garden Hose

Street Tee

 (not included)

1"

Suction Hose

Garden Hose Adapter (included)

Fig. 1

TABLE 1

 

CAUTION 

Undersize wire between the motor and the power source will adversely limit the starting and load carrying abilities of the motor. Minimum wire sizes 

for the motor branch circuits are recommended in Table 1.

TABLE 2 –  FRICTION LOSS CHART FOR PLASTIC PIPE:

For galvanized pipe, double the figures.

Loss of head in feet, due to friction per 100 feet of pipe.

Loss of head in meters, due to friction per 100 meters of pipe.

Nominal
Pipe Size
U.S. GPM

3/4"

1"

1-1/4''

1-1/2''

2''

4

3.75

1.15

0.30

0.14

5

5.66

1.75

0.46

0.22

6

7.95

2.45

0.65

0.31

7

10.60

3.25

0.86

0.41

8

13.50

4.16

1.10

0.52

9

16.80

5.17

1.35

0.65

10

20.40

6.31

1.67

0.79

0.23

11

24.40

7.58

1.98

0.95

0.27

12

28.60

8.85

2.33

1.10

0.32

14

38.00

11.80

3.10

1.46

0.43

16

48.60

15.10

3.96

1.87

0.55

18

60.50

18.70

4.93

2.33

0.69

20

73.50

22.80

6.00

2.83

0.84

Nominal

Pipe Size

L/Min.

20mm

25mm

32mm

40mm

50mm

15

3.7

1.15

0.30

0.13

 20

5.3

1.64

0.43

0.19

 25

7.1

2.18

0.56

0.27

 30

13.5

4.13

1.08

0.49

35

16.3

5.00

1.31

0.61

40

23.5

7.30

1.90

0.88

0.25

45

28.3

8.74

2.31

1.07

0.29

50

34.2

10.60

2.79

1.32

0.38

55

40.7

12.60

3.32

1.56

0.46

60

48.1

14.90

3.92

1.85

0.54

65

55.7

17.30

4.45

2.15

0.63

70

63.8

19.70

5.20

2.46

0.73

75

72.2

22.40

5.89

2.78

0.83

Recommended Wire Gauge For Electrical Cord Length

HP

Volts

0-25 ft.

50 ft.

100 ft.

150 ft.

200 ft.

1/2

115

14

12

10

8

6

Summary of Contents for RJSE-75SS

Page 1: ...nderground sprinkler systems operating lawn sprinklers and a multitude of other general purpose applications This pump is suitable for installations where the vertical distance from the pump to the water level does not exceed 25 ft 7 6m including drawdown In offset installations friction losses in the suction pipe must be taken into consideration Refer to Table 2 Friction Loss Chart Less at high a...

Page 2: ... head in meters due to friction per 100 meters of pipe Nominal Pipe Size U S GPM 3 4 1 1 1 4 1 1 2 2 4 3 75 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 10 60 3 25 0 86 0 41 8 13 50 4 16 1 10 0 52 9 16 80 5 17 1 35 0 65 10 20 40 6 31 1 67 0 79 0 23 11 24 40 7 58 1 98 0 95 0 27 12 28 60 8 85 2 33 1 10 0 32 14 38 00 11 80 3 10 1 46 0 43 16 48 60 15 10 3 96 1 87 0 55 18 60 50 18 70 4 ...

Page 3: ...K OF ELECTRICAL SHOCK Before servicing motor operated equipment shut off the power at the main electrical panel and disconnect the power supply from the motor and the accessories Use safe working practices during servicing of equipment a Lubrication The pump requires none Refer to motor manufacturer s instructions for motor lubrication b Replacing Mechanical Seal See Fig 2 Disassembly 1 Shut off t...

Page 4: ...s other than those for which it was designed and manufactured 2 Product not installed in accordance with applicable codes ordinances and good trade practices 3 Product connected to voltage other than indicated on nameplate 4 Pump used to circulate anything other than fresh water at approximately room temperature 5 Pump allowed to operate dry fluid supply cut off 6 Sealed motor housing opened or pr...

Page 5: ...onal d Electricité NEC et aux codes et ordonnances locaux Employez un électricien autorisé La pompe à injection pour arroseurs est un appareil polyvalent qu on peut employer pour augmenter la pression des petits systèmes souterrains d arrosage pour alimenter les arroseurs de pelouse et pour de nombreuses autres applications générales Cet appareil convient bien aux installations où la distance vert...

Page 6: ...teur de tuyau d arrosage compris Tuyau flexible d arrosage Vers le système d arrosage Vers une prise de courant de 115 volts mise à la terre Socle Fig 1 Poignée Diamètre nominal du tuyau Gallons U S par min 3 4 po 1 po 1 1 4 po 1 1 2 po 2 po 4 3 75 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 10 60 3 25 0 86 0 41 8 13 50 4 16 1 10 0 52 9 16 80 5 17 1 35 0 65 10 20 40 6 31 1 67 0 79...

Page 7: ... 11 pour permettre à la pompe de se vider 4 Retirez les 4 boulons 1 et enlevez le boîtier 2 5 Tirez le diffuseur 3 hors du boîtier à l aide de 2 tournevis plats pour faire levier 6 Retirez le déflecteur de ventilateur 4 et insérez un tournevis dans la fente de l arbre pour l empêcher de tourner lors du dévissage de la turbine 5 dans le sens antihoraire 7 Faites glisser le joint rotatif 6 de l arbr...

Page 8: ... fabriqué 2 Le produit n est pas installé dans le respect des codes et règlements applicables et selon les bonnes pratiques acceptées dans l industrie 3 Le produit a été branché à une tension autre que celle indiquée sur la plaque signalétique 4 La pompe a été utilisée avec des liquides autres que de l eau douce approximativement à la température ambiante 5 La pompe a fonctionné à sec alimentation...

Page 9: ...s y sistemas de contacto a tierra deben cumplir con el Código Eléctrico Nacional NEC y con cualquier código y ordenanza local Contrate los servicios de un electricista con licencia AVISO RIESGO DE DESCARGA ELÉCTRICA Estabombatieneunconductoratierrayunenchufedeacoplamiento del tipo con conector a tierra Para reducir el riesgo de una descarga eléctrica asegúrese que esté conectada solamente a un tom...

Page 10: ...n la tabla 1 se recomiendan los calibres mínimos para los cables de extensión del motor Tee de Calle no se incluye Fig 1 TABLA 1 Tamaño nominal de tuberia Galones Americanos min 3 4 pulg 1 pulg 1 1 4 pulg 1 1 2 pulg 2 pulg 4 3 75 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 10 60 3 25 0 86 0 41 8 13 50 4 16 1 10 0 52 9 16 80 5 17 1 35 0 65 10 20 40 6 31 1 67 0 79 0 23 11 24 40 7 58...

Page 11: ...el sistema de agua para liberar la presión 3 Retire los tapones de drenaje 11 y del cebador para permitir que la bomba se drene 4 Retire los 4 tornillos 1 y retire la caja 2 5 Haga palanca para retirar el difusor 3 de la caja utilizando 2 destornilladores ranurados 6 Retire la carcasa del ventilador 4 e inserte un destornillador en la ranura del eje para evitar que gire mientras desatornilla la tu...

Page 12: ...to se utiliza para propósitos distintos a aquellos para los cuales fue diseñado y fabricado 2 El producto no fue instalado de conformidad con las normas reglamentos y prácticas comerciales aceptadas 3 El producto se conecta a un voltaje distinto al que se indica en la placa de identificación 4 La bomba se utilizó con fluidos distintos al agua dulce a temperatura ambiente aproximadamente 5 La bomba...

Reviews: