GETTING STARTED - UNPACKING & SPECIFICATION
1.1
UNPACKING THE HOIST
The hoist will have been packed into a cardboard box or palletised (see weight details in specification)
Handling of all models of hoist & trolley will require lifting equipment and shouldn’t be moved by hand.
WHEN UNPACKING:
Ensure that both hoist and any ancillary equipment are recovered from the packaging. Small or delicate items may have been packed
separately. Check the contents against the supplier’s delivery note and advise the supplier immediately of any shortages.
Ensure that the hoist and ancillary equipment are undamaged. If the goods do not reach you in perfect condition, notify your supplier
immediately of any damage. Do not proceed with installation if the goods are damaged.
Ensure that a certificate of test and thorough examination together with a ‘CE’ certificate of conformity is included with the goods. Hand these
to the ‘responsible person’ for safe keeping. Check that the identifying mark (serial no), the safe working load (lifting capacity) and the ‘CE’
mark appear on the hoist.
SUPPLIER / MANUFACTURER
Red Rooster Lifting Ltd
Red Rooster Lifting Ltd
ADDRESS
Nauta House, The Meadows
Unit 26 Kelvin Way Trading Estate
Oldmeldrum, Aberdeenshire
Kelvin Way, West Bromwich
UK, AB51 0EZ
West Midlands, U.K. B70 7TW
TEL NO
01651 872101
0121 525 4162
MODEL
TCR-6000/2
SERIAL NO
SWL
6000 KG
DATE OF PURCHASE
NAME PLATES
The name plate gives important information which must be retained. Hoist serial number, SWL, model, air pressure, air flow, hoist rating, chain
size, speed, year of manufacture and the manufacturers name and address.
ATEX - Explosive protection
In Europe and several parts of the world the use of non-electrical equipment in hazardous areas is covered by the ATEX 2014/34/EU Directive.
(Previously ATEX 94/9/EC)
As standard most Red Rooster hoists are rated for Zone 2 use (Ex Group II 3 GD Ex h IIA T4 135°C)
The mini hoist TCR-250 & TCR-500/2 plus the TCS500 & TCS980/2 are not Zone 2 rated as standard, but can be rated for Zone 1.
The majority Red Rooster hoists for use in an ATEX area will come certified for Zone 1 – Ex Group II 2 GD Ex h (IIB or IIC) T4 (135°C)
The following models can also be rated for mining (Ex IM 2) – TCR-500 to TCR-2000/2, TNC and TMH models. These hoists can be used
according to Equipment Group I Category M2 where equipment is intended to be de-energised in the event of an explosive atmosphere.
The TCR-250, TCR-500/2, TCS-500 and TCS-980/2 models cannot be rated for mining.
CERTIFICATION
All new hoists are supplied with standard certification: Thorough Examination, EU Declaration of Conformity, which includes ATEX certificate
where required. Other documentation is available by agreement.
IN THE EVENT OF ANY PROBLEMS OR SHOULD YOU REQUIRE ASSISTANCE CONTACT THE SUPPLIER AS DETAILED ABOVE
QUOTING THE HOIST MODEL AND SERIAL NUMBER.
PACKAGING MATERIALS SHOULD BE RECYCLED OR DISPOSED OF ACCORDING TO LOCAL REGULATIONS.