16
Fig.15
Fig.16
Fig.16
Lighting Instruction
1.
Turn the LP gas tank valve OFF. Push control knob in, turn
OFF, and wait 5 minutes for any gas to clear.
2. Turn the tank valve ON. Push control knob in and rotate to
PILOT. Then push the igniter button until the burner is
ignited. If the burner fails to remain lit or becomes
extinguished, turn the burner completely off for 5 minutes
and then repeat step 2.
3. Once the burner has lit, continue to hold the control knob in
for 10 seconds, then release.
4. Turn the control knob from LOW to HIGH to the desired
heat setting.
For complete shutdown
1. Turn the knob to
”
Pilot
”
position first, then push in and turn
to
”
Off
”
position for complete shut off.
2. Turn the LP gas tank valve OFF before removing the LP
gas tank.
In case of failure of normal ignition, use the ignition bar
clamping a match to reach the burner for ignition through
the hole on the bottom of burner diffuser. Refer to figure
16.
WARNING
FOR YOUR SAFETY:
If at any time you are unable to light burner and smell gas,
wait 5 minutes to allow gas to dissipate before attempting
to light heater.
WARNING
FOR YOUR SAFETY:
DO NOT touch or move heater for at least 45 minutes after
use. Allow emitter and dome to cool before touching.
CAUTION:
Avoid inhaling fumes emitted from the heater’s
first use. Smoke and odor from the burning of oils used in
manufacturing will appear. Both smoke and odor will
dissipate after approximately 30 minutes. The heater
should NOT produce thick black smoke.
Igniter
push
HIGH
OFF
PILOT
LOW