10
5-TECHNICAL SPECIFICATIONS AND DIMENSIONS
INSTALLATION MEASUREMENTS
Distance between the hooks on the roof
(hooks for standard roofs and hooks for slate roofs)
Measurement unit
Collector height
mm
2270
Collector width
mm
1260
A*= distance between roof hooks of 1 collector
mm
Approx. 800-1060
B*= distance between the roof hook and the edge of the collector mm
Min.100
C**= vertical distance between the roof hooks
mm
2000-2200
* Variable interval (dependant on the width of the tiles and spacing of the beams).
** Variable interval (dependant on the height of the tiles).