28
8-FILLING WITH HEAT TRANSFER FLUID
FLOW REGULATION
Minimum recommended flow:
flat plate solar collectors: 25 l/m
2
h
E.g.: 6 m
2
x 25 l/m2h= 150 l: 60 min.= 2.5 l/min.
Flow meter with integrated adjustment valve (indications in l/min). Adjust the calculated flow with a hexagonal allen wrench while the
pump is operating (clockwise rotation reduces the flow).
See solar pump station manual.
ELECTRICAL CONNECTIONS
Electrical devices must be installed by qualified staff according to the standards in force and the specifications of the local competent
authorities.
Summary of Contents for HIGH PERFORMANCE SOLAR COLLECTOR
Page 35: ......