NOTE:
When GENLOCK is selected as the sensor shutter reference, shutter start timing (SHUTTER PHASE) may
still be adjusted. HD-SDI monitor outputs will automatically sync to the external GENLOCK signal as soon as it
is detected, there is no need to enable this function. Sensor shutter sync to GENLOCK is only supported with
HD-SDI.
PIN
SIGNAL
DESCRIPTION
1
GROUND
Common Ground
2
SS/GPI
Shutter Sync/GPI Trigger Input
3
TIMECODE
SMPTE unbalanced timecode Input
4
GENLOCK
RS170A Tri-Level Sync Input
The Camera BRAIN’s Shutter Sync/GPI Trigger uses a 3.3 V Schmitt trigger (5 V tolerant). It is not a switch
closure circuit. Therefore, it requires current supplied by the trigger source. Both edges of the input signal may
be used as a trigger.
For example, when GPI trigger is used for Record Start/Stop.
Start Record
: On Ground to 3.3 V transition
During Record
: Hold at 3.3 V
Stop Record
: On 3.3 V to Ground transition
During Stop
: Hold at Ground
SYNC (Video Sync) Connector
Mating Connector: FGG.00.304.CLAD27Z
Summary of Contents for SCARLET-X
Page 1: ...EPIC SCARLET V5 1 DRAGON MYSTERIUM X RED COM RED DSMC O PERAT ION GU IDE ...
Page 154: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 1 REV H 154 SIDE VIEW ...
Page 155: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 1 REV H 155 TOP VIEW ...
Page 156: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 1 REV H 156 BOTTOM VIEW ...
Page 157: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 1 REV H 157 BACK VIEW ...