2 INSTALLATION
2.2
Charge Profile Selection (ORANGE Wire)
The ORANGE wire is used to select the Maximum output voltage. This is achieved by connecting in the
following way:
• To select
Profile A
leave the ORANGE wire disconnected. This will set the Maximum voltage to 14.6 V.
• To select
Profile B
connect the ORANGE wire to Common Ground. This will set the Maximum voltage
to 15.0 V.
• To select
Profile C
connect the ORANGE wire to the RED wire (Input source positive). This will set the
Maximum voltage to 15.3 V.
• To select the
Li Profile
connect the ORANGE wire to the GREEN wire (LED output). This will set the
charger to Lithium mode.
CAUTION
Check the manufacturer’s data for your battery and ensure that the Maximum voltage of the profile you
select does not exceed the manufacturer’s recommended maximum charging voltage. If the Maximum
voltage is too high for your battery type, please select another charging profile.
Not
Connected
Orange Wire
Orange Wire
Orange Wire
Red Wire
Input
Source
Positive
Midi Fuse
Green Wire
Optional
LED
Orange Wire
FIGURE 2.2.1:
Charge Profile Selection