10 | Product Function
2.2 Battery Test Mode
The Battery Charger enters a battery test mode every 100 seconds to check that the input being
received from either solar or vehicle battery is still valid and that the auxiliary battery is still correctly
connected to the output. This feature protects the vehicle start battery from over discharge as well
as protecting the vehicle and its wiring in the event of damage to the output connection.
2.3 Green Power Priority
Green Power Priority is an automatic function that defines the order that input sources are
prioritised. This ensures that your battery will always take as much power as possible from solar
panels before supplementing from other sources. This lightens the load on your vehicle alternator
and maximises the collection of free solar energy.
Charging source priority is given in the following order:
1.
Solar (unregulated, 12 V solar panel)
2.
Alternator (via the Start Battery while the vehicle is running)
BCDC