18 | Installation
3.5 Fusing
"Figure 3.2.1.1: Typical Battery Setup" (page 12)
fuses are required to protect
the
RED
Vehicle Input cable and the
BROWN
Output cable. REDARC recommends the
RED
cable
fuse to be mounted within 100 mm cable length from the vehicle start battery positive terminal.
The
BROWN
Output cable fuse should be mounted within 100 mm cable length from the auxiliary
battery positive terminal. Refer to
"Table 3.5.1: Fuse Rating" (page 18)
for the appropriate fuse
sizing for each Battery Charger variant.
Table 3.5.1:
Fuse Rating
Charger Model
Charger Current
Rating
Vehicle Input and Output
Fuse Ratings
Recommended
Fuse Kit
BCDCN1225
35 A
40 A
FK40
BCDCN240
55 A
60 A
FK60
REDARC recommends using MIDI style bolt down fuses as they ensure a low resistance
connection. Blade type fuses are not recommended as they can result in a high resistance
connection which causes excess heat and may damage the fuse holder and/or the wiring.
Self-resetting circuit breakers are not recommended as they may trip prematurely due to
the heat generated by the current flowing through the cables.
When installing MIDI Fuses, ensure that the nuts securing the fuse and cable lug are tightened all
the way down to avoid high resistance connections (see
"Figure 3.5.2: MIDI Style Bolt-Down Fuse"
).
Figure 3.5.2:
MIDI Style Bolt-Down Fuse
MIDI Fuse
MIDI Fuse Assembly
Summary of Contents for BCDCN1225