20 | Installation
3.7.2 COMMON GROUND — BLACK CABLE
The
BLACK
wire must be connected to a ground point that forms a common ground with both the
start battery and the auxiliary battery. Most commonly the vehicle electrical systems ground/earth
reference is the metal of the bodywork. See
"Figure 3.4.2: Typical Cable Connectors — Portable
Auxiliary Battery System" (page 17)
and
"Figure 3.4.3: Typical Cable Connectors — Fixed
Auxiliary Battery System" (page 17)
for illustrations of how this may be achieved.
Figure 3.7.2.1:
Connecting the
BLACK
cable
Common Ground Connection
Connect the
BLACK
wire to a ground
point that is common with the start
and auxiliary battery.
3.7.3 PROFILE SELECTION — ORANGE WIRE
Connect the
ORANGE
wire to set the maximum output voltage to suit your selected Charge Profile.
If required to leave the
ORANGE
wire disconnected tape over the end of the wire.
"Table 3.7.3.1: Charge Profile Selection for Cabin Installation"
profile for your installation configuration.
Table 3.7.3.1:
Charge Profile Selection for Cabin Installation
Battery Type
Charge Profile
(25°C / 75°F)
Maximum Battery Voltage
Specification
AGM/Gel
A
14.6
Standard Lead Acid
B
15.0
Calcium
C
15.3
Lithium
Li
14.5 (LiFePO
4
)
CAUTION
Check the manufacturer’s data for your battery and ensure that the Maximum voltage of the
Charging Profile you select does not exceed the manufacturer’s recommended maximum
charging voltage. If the Maximum voltage is too high for your battery type, select another
Charging Profile.