9
1
INTRODUCTION
Storage Mode
Storage mode is designed to charge the house battery to its optimal level and
maintain that level while your caravan is in storage. This mode requires all loads to
be switched off or disconnected from the house battery before charging. It uses a
8-stage charging profile consisting of Desulphation, Soft Start, Boost, Absorption,
Battery Test, Equalise, Float and Maintenance stages (see Figure1.4.2). Storage
mode is designed to detect a wide range of battery fault conditions, for more
information on these fault conditions, please refer to the Troubleshooting section
of this manual. Unlike Touring mode, Storage mode does not cycle. This means
that when the charging process is completed, The Manager15 will always
remain in either Float or Maintenance stages. Float stage will provide the house
battery with a ‘trickle’ charge whenever the house battery voltage drops below a
predetermined threshold to ensure the battery stays charged. Maintenance stage
turns The Manager15 output off, but continues to monitor the house battery and
will revert to Float stage when necessary.
NOTE: If The Manager15 is set to Storage mode and the vehicle is started
The Manager15 will automatically switch to Touring mode once it senses an
increase in input voltage from the alternator.
When using the charger in Storage mode, make sure that all loads are disconnected from
the house battery under charge. Failure to do so may cause the house battery to be under
charged, give false readings on the State of Charge indicator and possibly cause damage
to any loads connected.
BA
TTER
Y TEST
FLO
AT
SOFT ST
AR
T
DESULPHA
TION
Desulphation*
Current
Storage Mode Charging Process
BOOST
ABSORPTION
MAINTENANCE
EQU
ALISE
Maintenance
Float
Equalise*
Absorption
Boost
Soft Start
Batt. Test
Voltage SLA