2 INSTALLATION GUIDE
2.3.1 Input Wire Diameter Selection
REDARC recommends the installer use cabling and connections between 8B&S
and 6B&S automotive. REDARC recommends that the input wire be of the size
outlined in Table 2.3.1.
Distance from input to
The Manager15
Recommended Cross
Sectional Area (mm²)
Recommended
Diameter Equivalent
Recommended
Fuse Size
≤3m
8
8 B&S
40A
3 - 5m
13
6 B&S
5 - 8m
21
4 B&S
At hotter temperatures the current handling ability of a cable is reduced. Ensure cable
diameter is increased when routing in hot areas such as the engine bay.
As a guide, when routing in hot areas such as the engine bay, move to the next
cable diameter size in figure 2.3.1, i.e. for an engine bay install of less than 3m
in cable length, upgrade the cable from 8mm² to 13mm².
2.3.2 Output Wire Diameter Selection
REDARC recommends the installer use cabling and connections between 8B&S
and 6B&S automotive. REDARC recommends that the output wire be of the
size outlined in Table 2.3.2. For longer runs using 10mm² is recommended (the
recommended maximum length is 5m).
Distance from The
Manager15 to House
battery
Recommended Cross
Sectional Area (mm²)
Recommended
Diameter Equivalent
Recommended
Fuse Size
≤2m
4
6mm AUTO or 10 B&S
20A or 23A
2 - 3m
6
10 B&S
3 - 5m
10
6 B&S
Figure 2.3.2 - Recommended output cable size