INSTALLATION GUIDE
Typical Setup
*1
The size of this fuse relates to the total current
draw of all the loads connected to the House
Battery, and should be rated slightly higher than
this. REDARC recommend the use of MIDI Style
Fuses.
*2
Essential loads are loads which must be left on
at all times, until the battery is flat. Non-essential
loads are those switched off when the battery
reaches a particular low-charge level, which can
be set in the ‘Advanced Settings’ menu.
*3
Both CANBus connections can be used for
either the Display or Battery Sensor
*4
Ensure the Voltage and Temperature Sensor
(Red terminal) on the House Battery Sensor is
connected to the House Battery Positive Terminal.
A single fuse and holder
setup from the Fuse Kits
available from REDARC.
Part number FK40 (40 A) or
FK60 (60 A).
MODEL
AC INPUT
VEHICLE INPUT
SOLAR INPUT
BATTERY OUTPUT
BMS1230S3
230V, 50-60Hz, 560W
9 - 32VDC, 520W
9 - 32VDC, 520W
12VDC Nom./ 0-30A
Please refer to owners
manual for appropriate wire
gauge and fuse ratings.
The Redarc CAN system is
designed to operate Redarc
CAN based devices only.
WARNING: Before obtaining access to terminals, all supply circuits must be disconnected
30
AMPS
LITHIUM
PROFILE
PROFILE
LiFe
PO
4
Solar
Panel
50 A
Fuse
Not
supplied
Start
Battery
Remote
Monitor
BMS1230S3
+
+
+
AC Mains/Shore Power
from mains power
(rear side)
AC
MAINS
-
+
House
Battery
1 2 3 4 5 6
Battery
Sensor
40 A
Fuse
Not
supplied
Ignition
Trigger
SBI12-BLD
Essential Loads*2
Non-essential
Loads*2
Load
Fuses
Not
supplied
*1
*3
*3
Voltage and
Temperature
Sensor *4
FIGURE 2.4.4.2:
Typical setup.