The Load Disconnect setting will output a GROUND relay trigger signal based on a
user set SoC or voltage level.
Disconnect Trigger Screen
Low Voltage Alarm Screen
Advanced Settings Screen
Set DC Input Trigger Screen
The Disconnect Trigger setting can be set to Disconnect (Loads OFF), Connect
(Loads ON) or to operate from either SoC or Voltage level triggers.
Next Menu Item
Change Setting
Back
Change Setting
If either Voltage or SoC are selected at the Disconnect Trigger setting screen the
Disconnect trigger level will need to be selected.
Once the Disconnect trigger level is selected the Reconnect trigger level must
be selected. Note that there is a built in minimum hysteresis constraint on this
setting and a nonadjustable time delay exists to stop repetitive switching.
Next Menu Item/Confirm
Increase Setting
Back/Cancel
Decrease Setting
Should the Load Disconnect feature be triggered the Remote Monitor will prompt
the user to allow the Loads to be reconnected for 10 minutes. This allows the
user to temporarily use power (for loads such as lighting)to rectify any issues
and/or engage another charging source. After this time has lapsed the load will
disconnect and the prompt will reappear, unless the battery voltage is above the
Disconnect level.
Load Disconnected
Turn Loads ON for 10
minutes
N/A
Load Temporarily
Connected
No
N/A
The DC Input Trigger allows you to select whether you would like your DC input to be
triggered via Ignition, automatically via The Manager30, or at a specific voltage.
Set DC Input Trigger Screen
Load Disconnect Screen
Advanced Settings Screen
R-Bus Diagnostics Screen