20
2
INSTALLATION GUIDE
2.4.3 Connecting the Battery Sensor
Wire the Battery Sensor as shown in Figure 2.4.3.1 ensuring that the Voltage and Temperature Sensor
(RED terminal) connects to the house battery positive terminal. This lead measures voltage and
temperature at the battery. The “BNEG” stud connects to the House Battery negative terminal and the
“GND” stud connects to the vehicle common ground point. Connect the CANBus Connection cable to
either of the main unit CANBus interfaces.
to Vehicle
Common (Chassis
Ground “GND”)
to House Battery Positive Terminal
(Voltage and Temperature Sensor)
to House Battery
Negative Terminal (“BNEG”)
to CANBus
Interface
CANBus
Connection
FIGURE 2.4.3.1:
Battery Sensor connections
2.4.4 Wiring the Main Unit
Refer to Figure 2.4.4.1 for required connections and to Figure 2.4.4.2 typical setup.
Ground
1
3
5
6
Solar Input
AC Mains Input
DC Input
Battery Output
4
2
Load Disconnect
Ignition Trigger
CANBus Interface
AC
MAINS
CANBus Interface
FIGURE 2.4.4.1:
Required connections.
NOTE:
If a longer Remote Monitor cable is required, a replacement CAT5 patch cable may be used, up to
a length of 32' (10 m).