25
3
USER GUIDE
3.3
Initial Setup
When The Manager30 is first switched on the unit will prompt the user to enter a number of settings. It is
important to enter these settings accurately as they directly affect the operation and performance of The
Manager30.
Set the Language:
The first step required for initial setup is Language selection. Once entered the Language
is set in memory and retained should power be lost and reconnected.
Edit Battery Type and Size
About Screen
N/A
Remote Settings Screen
Setup your Battery Type:
The second and most important step required for initial setup is Battery Type and Size
selection. Please refer to the battery manufacturers specification sheet for Size(AH) and
Type specifications. If you are unsure of the type of your battery please select the Gel
setting. Should power to the Battery Sensor be removed at any time, the unit will revert
to the Gel setting and prompt the user to input their Battery Type again. The Battery Size
setting will be retained in memory.
Edit Battery Type and Size
About Screen
N/A
Remote Settings Screen
Setup the Date and Time:
The final step required for initial setup is selecting the Time and Date to be displayed on
Remote Monitor. Time and Date settings are used not only for the clock screen but also on
the Charge per Hour and Charge per Day log screens.
The Time and Date settings are not retained in memory so in the event that the charger
loses ALL power sources (Input and Output), upon reconnection the unit will prompt the
user to enter the Time and Date again.
The Clock screen is also the default Home Screen.
Set the Time and Date
Charging Status Screen
N/A
Battery Charge Screen
CAUTION
When charging a battery, make sure the settings at the Battery Setup menu on the Remote Monitor
are correct for the type of battery under charge. Charging a battery with the wrong profile may cause
The Manager30 to indicate a fault or give misleading results and could result in damage to the battery.
Noticeable oscillations between Boost and Absorption stages indicate the wrong choice of battery type.
Check and adjust battery type. If you are unsure of the battery type or settings to use, set The Manager30
to the Gel setting.