33
3
USER GUIDE
If The Manager30 detects a problem with the charging system that prevents it from
continuing to charge the battery, it will alert you via a ‘Fault’ screen and an alarm buzzer,
and will instantly terminate the charging cycle until the fault condition is cleared. The
screen will give a brief description of the problem and will allow you to select either ‘Clear’
or ‘Ignore’. Both options will clear the fault screen. After selecting ‘Clear’, however, The
Manager30 will immediately check to see if the fault condition still exists. If it doesn’t, the
unit will restart charging. Selecting ‘Ignore’ will simply hide the fault screen for up to one
minute. It will not allow The Manager30 to recommence charging unless The Manager30
itself detects the removal of the fault condition.
NOTE:
If “Ignore” is selected but the fault is not removed, when the warning re-appears
after one minute, it will not be accompanied by the alarm buzzer.
The troubleshooting section (3.7) of this manual contains a description of faults detected.
Clear Fault
N/A
Ignore Fault
N/A
3.7
Troubleshooting
The Manager30 is designed to detect and advise the operator of a variety of fault conditions and will
terminate the charging cycle immediately should a critical fault be detected. This ensures that it will not
attempt to charge a faulty battery, which protects The Manager30, house battery and most importantly
the user.
The Remote Display is used to inform the user of the nature of the problem whenever possible. These
indicators should be used to diagnose, and if possible correct any faults that may occur. When attempting
to diagnose a fault, cabling should be adequately rated and all components, including all input sources
and house battery should be connected as close as possible to The Manager30.
The probable cause and recommended action to take when faults occur with The Manager30 system
are listed in section 3.7.1. If a fault still occurs after following the recommended action, please contact
REDARC for further diagnosis.
REDARC Corporation
power@redarcelectronics.com
www.redarcelectronics.com
USA: +1 (704) 247-5150
Canada: +1 (604) 260-5512
Mexico: +52 (558) 5326-2898