THE SOLAR REGULATOR
REGULATOR FUNCTION
CONNECTION
The regulator should be connected to the battery according to the diagram above. The connection order
is indicated by the numbers circled.
Incorrect connection of the battery can damage the regulator.
The Remote temperature sensor is optional and the regulator will still operate without it connected.
The Remote monitor is optional and the regulator will still operate without it connected.
INDICATION
1. LED fl ash (fast)
Short circuit - check the Solar panel and the battery to make sure that they
are
connected
correctly.
2. LED fl ash (slow)
Fully charged.
3. LED
ON
Charging.
4. LED fl ash (occasional) Battery connected, no charge current.
5. LED OFF
No connection or Over voltage - Check wires, reduce current draw (load),
reset
the
controller.
+
+
+
-
-
-
2
1
6
5
4
3
Temperature sensor
Charging battery 1
Charging battery 2
Set
MODE
Battery type
Charge Priority
Charge Frequency
Remote
temperature
sensor
Remote
meter
(optional)
1
2
1
7