background image

SETTING MODES

1.  Press the Set button to start the mode select process.

2.  Press the Set button to cycle through to the mode required.

• Battery 

Type

• Charge 

Priority

• Charge 

Frequency

3.  Once the correct mode is selected, press and hold the Set button for 5 seconds, until the LED and  

setting begin to fl ash, to change the setting for the selected mode.

4.  Press the Set button to cycle through the settings.

5.  Once the desired setting is selected, leave the Set button for 5 seconds to save the setting and 

return to the mode select process.

6.  Once all modes have been set, leave the Set button for 5 seconds and the mode select process will 

end.

MODES

1st LED - Battery type 

 

 

         3rd LED - Charge Frequency

Setting

Battery Type

Setting

PWM Frequency

1

AGM/Gel

0

25Hz (Factory set)

2

Lead Acid

1

50Hz

2nd LED - Charge Priority

Setting 

Battery 1 %

Battery 2 %

0

0%

100%

1

10%

90%

2

20%

80%

3

30%

70%

4

40%

60%

5

50% (Factory set)

50%

6

60%

40%

7

70%

30%

8

80%

20%

9

90%

10%

When setting the charge priority, only Battery 1 
percentage needs to be set.  Battery 2 percentage 
is automatically calculated by the regulator.

During normal charging the regulator will divide 
the charging as per the settings.  If Battery 1 is 
fully charged, more charge will go to Battery 2.  If 
Battery 2 is disconnected all the charge current will 
go to Battery 1.

If MODE LED fl ashes ‘H’, the temperature exceeds 
55°C and the units temperature protection is 
active.  The unit will restart once the temperature is 
within safe limits.

8

Summary of Contents for SMK1090

Page 1: ...Monocrystalline Portable Folding Solar Panel Kits...

Page 2: ...nto contact with your eyes or skin immediately wash the affected area with cold running water and seek medical assistance Eye protection and gloves should be worn when handling lead acid batteries The...

Page 3: ...gulator 7 Regulator function 7 Connection 7 Indication 7 Setting modes 8 The display screen 9 Monitor function 9 Screen function 9 Monitor operation 10 System wiring 11 Installation notes 11 Standard...

Page 4: ...FOLDING SOLAR MODULE Custom Designed Legs Strong Hinges Diode Protected Junction Box Quality MC4 Connectors Tempered Glass Coating Monocrystalline Construction Plastic End Caps Strong Aluminium Frame...

Page 5: ...90W 2 x 45W Max system Voltage 1000VDC Net Weight 11kg Frame Anodized Aluminium Dimensions Closed 610x534x80mm Cable length 5000mm Dimensions Open 610x1076x35mm Operating temp 40 to 85 C Max power Vo...

Page 6: ...120W 2 x 60W Max system Voltage 1000VDC Net Weight 14kg Frame Anodized Aluminium Dimensions Closed 810x534x80mm Cable length 5000mm Dimensions Open 810x1076x35mm Operating temp 40 to 85 C Max power V...

Page 7: ...W 3 x 50W Max system Voltage 1000VDC Net Weight 16 5kg Frame Anodized Aluminium Dimensions Closed 610x534x120mm Cable length 5000mm Dimensions Open 610x1630x35mm Operating temp 40 to 85 C Max power Vo...

Page 8: ...nal and the regulator will still operate without it connected INDICATION 1 LED flash fast Short circuit check the Solar panel and the battery to make sure that they are connected correctly 2 LED flash...

Page 9: ...will end MODES 1st LED Battery type 3rd LED Charge Frequency Setting Battery Type Setting PWM Frequency 1 AGM Gel 0 25Hz Factory set 2 Lead Acid 1 50Hz 2nd LED Charge Priority Setting Battery 1 Batte...

Page 10: ...rror LED Charge LED Screen Mode Button Left Button Right Button Set Button Mounting Frame 1 2 Battery 1 Icon Battery 2 Icon Solar Icon Remote temp Icon Temperature sensor Icon Setting Icon Error Icon...

Page 11: ...Right Left KEY 1 1 2 2 2 1 Set Backlight Timeout Set Backlight Brightness Set Temperature Units Set Data Repeat option See below Set Time hours Set Time minutes Press OR OR OR OR OR OR This will cycl...

Page 12: ...ntent or both of AGM type The supplied MC4 connectors are suitably rated for up to 30A if multiple panels are used to the point of exceeding this rating alternative connectors should be sourced When c...

Page 13: ...fuses must be used and should be determined according to specific installation requirements 1 5m Supplied 5 0m Supplied Cable kits available for second battery installation Amorphous Flexible and Fol...

Page 14: ...Redarc that are designed for use in recreational vehicles and boats not otherwise specifically referred to in this clause 1 and 1 8 any component of or accessory for any product in clause 1 1 to 1 7...

Page 15: ...electrician or technician in accordance with the instructions of Redarc 11 If the Solar Product is found to be working satisfactorily on return to Redarc or upon investigation by Redarc the Purchaser...

Page 16: ...arc Electronics Pty Ltd All rights reserved This product is manufactured in China AUSTRALIAN DESIGNED AND ENGINEERED This product has been specified and tested in Australia in accordance with REDARC s...