SYSTEM WIRING
WIRING PRECAUTIONS
• Ensure that all connections are made using REDARC recommended connectors and cables or
other suitably rated connectors and cables.
• Ensure that total system current does not exceed the maximum current rating for either the
cables or any connectors that are subject to the total current of the system.
• Ensure that grounding and fusing is adequate for the system as per wiring diagrams on
pages 12 and 14.
• Ensure that all MC4 connections are crimped with the correct MC4 crimping tool. Contact
REDARC for more information on purchasing this tool.
• All cable entries into the vehicle must be suitably sealed, REDARC Single or Double Cable Glands
are recommended.
• If your regulator has a dedicated solar input ground (negative) terminal ensure that the negative
ground from your solar panels is connected here.