background image

10

www.redbacklasers.com.au

ARL516G

TM 

TECHNICAL SPECIFICATIONS

Laser Wavelength

522-542nm <5mW

Laser Class

3R

Range with Receiver

600m Diam Rotating

Horizontal Accuracy

±3mm/20m

Rotation Speeds

High, Medium, Low

Scan Angles

0

o

 - 20

- 40

o

Self Levelling Range

±3.5

o

Temperature Range

-10

o

C - +40

o

C

IP Dust Water Resistance

IP66

Power

4 x “C” Alkaline or Ni-Mh pack

Low Power

Power LED Flash

Size

162x180x202mm

Weight

2.55Kg

Technical Specifications

Calibration & Self Check

All Redback Lasers have been checked for calibration and certified by one 

of our technicians here in Australia prior to despatch and should under 

normal conditions not go out of calibration.  A calibration certified sticker 

with the date and name of technician is located on the laser itself.  It is 

worth checking calibration from time to time particularly after any known 

knocks or drops.  An easy way to continually check calibration is to always 

double check you work with the laser located in a different position or use 

an alternate vertical line.  Various other methods for checking calibration can 

be found at 

www.redbacklasers.com.au/downloads 

or the laser can 

be returned to our service department for checking and re-calibration.  We 

at Redback Lasers provide a once off free calibration and check within the 

duration of the warranty period see page 12 for details.

Summary of Contents for ARL516G

Page 1: ......

Page 2: ...strument or attempt to perform any internal servicing Repairs and service should be performed only authorised service centres of Redback Lasers This instrument complies with the safety Classification standards of laser radiation 2 CAUTION Class 3R laser 5mW at 522 542nm Do NOT stare into laser beam or aim at another person Follow relevant Australian Standards Copyright CMI LasersTM RedBack lasersT...

Page 3: ... up on its side for vertical alignment and site layout The ARL516G with 4X brighter green beam laser technology together with scan line modes makes this ideal for visible indoor alignment and levelling Other features of the ARL516G include remote control rechargeable Ni Mh and Std C Size battery operation and Two Year Redback Warranty See page 12 www redbacklasers com au ARL516G Included Accessori...

Page 4: ...rechargeable 4 Keypad 5 Recharging Socket 6 Levelling Knob Side Mounted 7 Side Wall Mount 8 Datum Marker 9 Pendulum Locking Knob 10 5 8 11tpi Screw 2 4 6 9 Power On Off and LED Manual Bubble Vial for Side Mounted Operation Rotating Mode Speed Control Rotation Mode Scan Control Scan Mode 10 10 Keypad Scan Mode and LED 8 ...

Page 5: ...Reception Sensors Fine Coarse Mode Speaker Control Power On Off Rubber Casing LCD Display Repeated on rear Bubble Vial Display back light Magnetic Mounting Power Off only Scan Mode Rotating Mode Speed Control Rotation Mode Scan Control Scan Mode Operating LED ...

Page 6: ...plied rechargeable battery pack Handy Hints Prior to initial use charge the rechargeable batteries for at least 8 hours Running rechargeable batteries completely flat will increase battery life The ARL516G can operate off mains by plugging the charger for indoor use only into the unit Remember the ARL516G can operate using standard batteries when rechargeable pack is out of charge The ARL516G has ...

Page 7: ...16GTM starts by default in rotation mode and so the rotation button only needs to be pressed when switching from scan mode back to rotation Whilst rotating the speed of rotation can be changed by pressing the up and down arrow buttons on the keypad or remote Rotation speed will effect receiver performance at different distances and also help visibility of the laser beam when used indoors Turning L...

Page 8: ...ft and right to achieve this Once the dot is on the target use the receiver to pick up the rotating line on the second line of the 90 degree Your square is now set Rotation Scan Modes For Indoor Visibility The Scan Mode stops the laser from rotating and toggles the beam left to right intensifying the beam making the laser more usable indoors as a visible laser You can set the scan angle to 0o 20o ...

Page 9: ...15TM RECEIVER INSTRUCTIONS Indicates laser beam is below line slide receiver down Indicates laser beam is above line slide receiver up Indicates laser beam is on the line Power and Battery Life Indicator Coarse Fine and Speaker Indicator www redbacklasers com au A press of the power button toggles the receiver on and off The Speaker button toggles through 3 speaker volumes Pressing the Coarse Fine...

Page 10: ...ustralia prior to despatch and should under normal conditions not go out of calibration A calibration certified sticker with the date and name of technician is located on the laser itself It is worth checking calibration from time to time particularly after any known knocks or drops An easy way to continually check calibration is to always double check you work with the laser located in a differen...

Page 11: ...power up in normal Horizontal mode A Check the pendulum lock has been unlocked ON position for horizontal rotation operation Q The Laser does not power up A Check the rechargeable batteries are charged and connected correctly and or replace standard C size Alkaline batteries and check they are inserted correctly Q Using the receiver I get multiple heights showing as level A This is a common proble...

Page 12: ... Warranty CMI warrants that our products will be free from defects in material and workmanship for the warranty period CMI promises to repair or replace free of charge the product or part of product if found to be faulty due to defective workmanship or materials within the duration of the warranty as long as the following terms and conditions are met Product must not have been misused or abused mu...

Reviews: