TROUBLE SHOOTING
•
Keep laser and accessories stored in protective case.
•
Make sure laser is stored dry, dry out before storage to prevent damage.
•
Remove batteries when not used for an extended period of time to prevent
leakage.
•
The ARL516G
TM
is a precision instrument and should not be subjected to excessive
knocks, drops or vibrations.
•
Self check calibration from time to time. See page 9
•
For service contact Redback Lasers.
www.redbacklasers.com.au
Q.
I hear a continuous beeping in side (Vertical rotation)
mode!
A.
Check the pendulum lock is in the “OFF” Locked position when
used in vertical rotation mode on its side mount.
Q.
The Laser does not power up in normal Horizontal mode!
A.
Check the pendulum lock has been unlocked “ON” position for
horizontal rotation operation.
Q.
The Laser does not power up!
A.
Check the rechargeable batteries are charged and connected
correctly and or replace standard “C size Alkaline batteries and
check they are inserted correctly.
Q.
Using the receiver I get multiple heights showing as level!
A.
This is a common problem with all laser levels and is usually due
to the laser being reflected off a window or other reflective
surface. So the original laser beam plus the reflection are both
hitting the receiver at slightly different heights. To prevent this,
set the laser unit up so that you cannot see a reflective surface
from where you are holding the receiver i.e. Any glass behind
receiver not the laser.
www.redbacklasers.com.au
Care & Maintenance
Trouble Shooting - FAQ