Redback® A 4500C

 Evacuation Timer with Network Access

13 

Audio Out RCA Connectors 

 

Connect these outputs to the input of the background music amplifier.

14  

Bell Contact

 

 

These contacts are for remote triggering of the Bell tone. These could be triggered by a remote switch or other  

 

closing contact.

15  

Alert Contact

 

 

These contacts are for remote triggering of the Alert tone. These could be triggered by a remote switch or other  

 

closing contact.

16 

Evac Contact

 

 

These contacts are for remote triggering of the Evacuation tone. These could be triggered by a remote switch or 

 

other closing contact.

17  

Cancel Contact

 

 

These contacts are for remote triggering of the cancel function. These could be triggered by a remote switch or 

 

other closing contact.

18 

Mic Volume

 

Adjust this trimpot to adjust the A 4564 Microphone volume.

19 

RJ45 interface

 

This RJ45 port is for connection to the A 4564 microphone paging console.

20 

RJ45 interface

 

This RJ45 port is for connection to the A 4578, A 4579, A 4581 and A 4581V wall plates.

21 

Dip Switches

 

These are used to select various options. Refer to DIP Switch Settings section.

22  

24V DC Input (Backup)

 

 

Connects to a 24V DC backup supply with at least 1 amp current capacity. (Please observe the polarity)

23 

24V DC input 

 

Connects to a 24V DC Plugpack with 2.1mm Jack.

Summary of Contents for A 4500C

Page 1: ...e Wall Plate Hard Wired A 2081 Alert Evac Chime Cancel Remote Wall Plate Hard Wired A 4578 Alert Evac Cancel Remote Wall Plate U UTP Cat5 A 4579 Timer Isolate Remote Wall Plate U UTP Cat5 A 4581 Alert...

Page 2: ...users reliable products of high build quality with local product support We believe there is significant added value for customers when purchasing an Australian made Redback amplifier or PA product Lo...

Page 3: ...ng Events Using The Front Button 10 2 6 Deleting A Programmed Time 11 2 7 Reset All Programmed Times 11 2 8 EV Chanegover 12 2 9 Play Prebell 12 2 10 Play Music 12 2 11 Audio Connections 12 2 12 DIP S...

Page 4: ...tches or by the rear terminal contacts for remote activation The Alert Evac Bell and Cancel functions can also be activated via remote plates or the A 4564 Paging Console The Isolate function can be r...

Page 5: ...tes when an audio file from one of the Music Folders 5 99 is active 6 Menu and Navigation Switches These switches are used to navigate the menu functions of the unit 7 Isolate Switch This switch is us...

Page 6: ...0 for details 6 Backup Battery Switch Use this switch to activate the backup battery Note The backup battery only backs up the current time 7 Backup Battery Replace this battery with a 3V CR2032 only...

Page 7: ...tone These could be triggered by a remote switch or other closing contact 17 Cancel Contact These contacts are for remote triggering of the cancel function These could be triggered by a remote switch...

Page 8: ...inue to sound after the evac switch is mo mentarily pressed There is an automatic alert to evac switch over option associated with the front panel switches refer to section 2 8 Note 1 The tone that is...

Page 9: ...5 EV CHANGEOVER 00 00 00 Mon NO TIME__00 00 00 Menu Main Screen Press the UP and DOWN buttons to scroll up and down Enter Press the ENTER button to make your selection Menu Press the MENU button to e...

Page 10: ...his option allows the user to enter the Station Event information which includes the event Turn on time Period and Output After selecting this option the screen as shown in Fig 2 5a should appear Fig...

Page 11: ...s sets each day ON or OFF Use the up and down buttons to set the day to Y for ON and N for OFF Once the days of the week are set press the enter button to confirm and be returned to the main menu Repe...

Page 12: ...vals up to 600 seconds NOTE If the changeover time is set to 0 the changeover will be de activated and therefore the unit will not switch over from the Alert cycle to the Evac cycle automatically 2 9...

Page 13: ...olume setting on the individual volume control attenuator Alert Evac 24V Out These contacts are for switched 24V outputs whenever the alert or evac tones are activated These may be used to run externa...

Page 14: ...al To Ethernet Converter setup is complete and all required connections made the unit should now be acces sible via the PC software Refer to the supplied Software Programming Guide for more informatio...

Page 15: ...to 100m away using heavier guage cable which reduces the voltage drop across this distance and ensures the switch leds illuminate The Alert Evac Chime Cancel switches on the wall plate are connected...

Page 16: ...e to the A 4500C E v a c A l e r t C h i m e C a n c e l Alert Switch Chime Switch Evac Switch Alert Lamp Evac Lamp Cancel Switch A 2081 REMOTE WALL PLATE Chime Lamp N C N O Common 24V Out N C N O Eva...

Page 17: ...4581V wall plate is allowed to be connected to the A 4500C via the To Wall Plate RJ45 port If the wall plates have a connection problem with the A 4500C main unit the LED on the wall plate will flash...

Page 18: ...me on or off Note DIP 1 must be ON for the internal chime to function DIP switches 3 4 are not used Fig 4 1 5 3 A 4564 REAR PANEL CONNECTIONS 1 24V DC connector 2 1mm DC jack centre pin positive 2 RJ4...

Page 19: ...SD card not formatted properly ERROR4 Cannot find an MP3 to play ERROR7 Cannot Play MP3 ERROR8 Fault with Configuration File Power switch is illuminated Red but unit doesn t work Unit will not play M...

Page 20: ...at5e cabling max 300m CONTROLS Alert Evac Rear Volume Voice over Rear Volume Bell Rear Volume Prebell Rear Volume Music Rear Volume Power On Off Switch Alert Switch Illuminated Push Switch Evac Switch...

Reviews: