Overview: 

The SunRise Home Battery is an Australian-made product that is designed to reduce your electricity bill. It does this 
by storing your excess solar power for use at night.  It can also provide backup power for your essential loads during 
power outages. 

SunRise is designed to be easy to install and can be located either inside or outside. It should be placed in a shaded 
area. It can be placed on a 600x1200mm concrete base or be mounted on a wall on standard heavy-duty 
airconditioner brackets. All Circuit breakers and DC Isolators are included within the system, so no isolators need to 
be attached to the wall. 

This manual describes the installation of the Model: SGS 1-PH AUTO of the SunRise System.  

A 3-phase version of the SunRise is also available. 

The SunRise system can be installed with or without batteries. Batteries can easily be added later, as demand grows 
and budgets allow. Batteries must be of the same make and model. 

 

When installed with batteries excess PV solar electricity generated during the day will be used to reduce the 

amount of electricity imported from the grid at night. In addition the battery ensures essential household 

loads (fridges, lights etc) can be powered during a power outage. This uses an automatic transfer switch 

included inside the SunRise unit.   

 

When installed without batteries excess PV generated during the day can be exported to the grid, which 

reduces your electicity bill. Ensuring you have the best electricity plan from your provider will improve your 

return. 

 

The SunRise system can also easily be retrofitted to an existing PV solar system. 

The SunRise combines an AS4777.2 certified SunGrow 5kW inveter (SH5K-20) with the following battery options: 

Up to 5 LG batteries (48Vdc Lithium-ion 6.5KWh/3.3kWh nominal each – Model EM048126P3/EM048063P3).  

Up to 4 BYD Batteries (48Vdc Lithium-ion 2.56kWh nominal each – Model B – Plus Pro 2.5) 

This Installation Guide should be read in conjuction with the following Sungow, LG & BYD User Manuals supplied 
with the system. 

Installation should conform to AS/NZS 3000 & AS/NZS 5033. 

 

A total of 6.65kW of solar panels can be connected to the systems two 
MPPT’s to claim full STCs (1.33 x 5.0kW). The maximum DC  string 
voltage is 600Vdc.  

The SunRise SGS system can be remotely 
monitored via SunGrow’s web portal or via 
their their app (iSolarCloud app).  

RedEarth Energy Storage can also provide a 
remote monitoring service to ensure ongoing 

operation of the SunRise battery system. Contact RedEarth Tech 
Support on 0487 002 451. 

 

 

Overview: 

Summary of Contents for SunRise 1-PH

Page 1: ...SunRise Home Battery System Model SGS 1 PH AUTO with LG BYD battery Installation Manual...

Page 2: ...16 5kWh Each battery weighs 24kg Dimensions 104 cm H x 97 cm W x 54 cm D Safety Instructions Physical Specifications WARNING Installation and Maintenance of the Sunrise System should only be done by a...

Page 3: ...old loads fridges lights etc can be powered during a power outage This uses an automatic transfer switch included inside the SunRise unit When installed without batteries excess PV generated during th...

Page 4: ...imum of 6 65kW of panels and maximum PV string voltage of 600VDC 4 Optional Cat5E internet cable to provide more reliable comms for remote monitoring WiFi is included in the system as default In addit...

Page 5: ...ing the maximum 5 x 6 5kWh LG M48 batteries The 2nd image shows the SunRise SGS without the batteries in place Note The Sunrise is delivered with the inverter inside but without the batteries inside t...

Page 6: ......

Page 7: ...The internal wiring layout is shown below The right side of the SunRise system includes the AC and DC Switch assemblies the left side allows access to the control panel of the inverter...

Page 8: ...their solar inverters and removes the requirement to add AC and DC Isolators on the wall next to the system The system is supplied without the batteries installed This allows the enclosure to be more...

Page 9: ...er induction including system monitoring using the Sungrow app on their phone if possible Apply appropriate labels in on MSB see included SunRise Signage Overview document Complete a commissioning rep...

Page 10: ...f 5 x 3 3 kWh batteries Other battery options can be ordered including BYD and Troppo batteries 3 1 x Parts Kit containing all parts to complete the installation of the SunRise battery system in a nor...

Page 11: ...from the top 2 Wall mount The system can also be wall mounted using standard heavy duty airconditioning mounting bracket available from RedEarth These images show a SunRise system installed on a wall...

Page 12: ...LG battery cables KEEP SAME LENGTH AS SUPPLIED BY Redearthng up the FPA3 The diagram below shows an overview of the electrical connection inside the SunRise System STEP 4 Wiring up the Sunrise...

Page 13: ...cables to the PV isolator inside the SunRise 4 Optional Cat5E internet cable to the SunRise otherwise use Wi Fi Note All isolators and MCBs are included in the Sunrise so no wall mounted isolators are...

Page 14: ...f energy available is limited to the battery capacity and the solar contribution during the daytime The Parts Kit contains a 25A 2 pole MCB to isolate the Inverter Grid Solar and Essential EPS circuit...

Page 15: ...at right shows where to connect the cable in position 3 o Optional Remote Earth Fault Alarm Terminals are provided inside the SunRise system that provide 230Vac in the case of an Earth Fault These can...

Page 16: ...ries They are installed in the Bus bars provided and shown at right b Install the batteries with the battery terminals towards the front of the unit The batteries are lowered directly onto the battery...

Page 17: ...he battery terminal connections are correct if batteries are included in the system Start up the battery in the SunRise system if batteries are included otherwise skip this section LG Battery 1 Once c...

Page 18: ...attery has completed start up which takes 1 minute the indicators as shown below will be on For LG battery Trouble shooting refer to pp31 of the LG Installation manual which has been included with you...

Page 19: ......

Page 20: ...itself if you do not want to connect via your phone and Local Mode To access the control panel remove the vent on the left side of the system as shown here o Work through the settings on the SunGrow...

Page 21: ...e ordered from RedEarth together with the required communication and battery cables The procedure to add extra battery modules is outlined below The LG battery must be shut down to add modules Note th...

Page 22: ......

Page 23: ...gency Power Supply AC POWER EPS rated Power from battery only 3000VA EPS rated Power with PV support 5000VA Changeover time to EPS when outage occurs 3 sec Max Charging current 65A Max Discharging cur...

Page 24: ...l Voltage 51 2 Vdc Lithium ion chemistry LiFePO4 OPERATING CONDITIONS Operating voltage 40 56 4 Vdc Max float voltage 57 4 Vdc Available operating temperature C 10 50 C Certification UL1642 IEC62619 S...

Page 25: ...ons Miscellaneous spare parts o HD Air con bracket set with additional bolts o 4 core cable 3C E in 10mm2 and 16mm2 o Optional remote earth fault alarm 230Vac 3G 4G dongle if no customer internet is a...