DS3100
- 13 -
Oil change in conveyor belt gear unit (after every 100 operating
hours)
- Unscrew the filler screw (11).
- Loosen the drain screw (12) below on the inside, and discharge the oil.
- Screw in the drain screw (12) with a new gasket.
- Fill in 0.6 l of the oil
SAE85-W140
.
- Screw in the filler screw with a new gasket.
Used oil is a threat to the environment; dispose of it in
accordance with the environmental regulations.
9
11
10
12
Fig. 6: Conveyor gear unit
Setting overpressure and throttle valve
- Overpressure valve (10) can be precisely set using hexagon socket (fig. 6).
- Throttle valve (9) (fig. 6) for slider regulation (6) (see p. 10 – fig. 2). Set the machine only
in an empty state. Turn the throttle valve no wider than just to open the slider.
A wrong setting causes system overpressure. This may lead to serious
damage of the machine!