Table 45: Spec. - FCC & IC Certified Antennas: 5.8 GHz PMP Operation
Redline Part
Number
Description Application
Gain
(dBi)
GUI
Settings
Tx Peak
Conducted
Power
(dBm)
48-00014-00
ANTENNA, 60 DEG, 16 dBi,
5.150-5.875 GHz, BS,
1.43x0.82 FT (436x250 mm)
SECTOR FP
PMP 16 9 18.6
18.3
18.5
48-00017-00
ANTENNA, 90 DEG, 14 dBi,
5.150-5.875 GHz, BS,
1.43x0.82 FT (436x250 mm)
SECTOR FP
PMP 14 11 20.3
20.5
19.8
48-00028-00
ANTENNA, 60 DEG, 17 dBi,
5.250-5.850 GHz, BS, 2.13x0.7
FT (650x216 mm), SECTOR FP
PMP 17 8 17.2
17.3
16.8
48-00029-00
ANTENNA, 90 DEG, 16 dBi,
5.250-5.850 GHz, BS, 2.13x0.7
FT (650x216 mm), SECTOR FP
PMP 16 9 18.6
18.3
18.5
48-00047-00
ANTENNA, 120 DEG, 15 dBi,
5.15-5.875 GHz, BS, FP
(550x250 mm)
PMP 15 10 19.4
20.1
18.7
48-00065-00
ANTENNA, 120 DEG, 15 dBi,
4.9-5.9 GHz, SECTOR FP
PMP 15 10 19.4
20.1
18.7
48-00067-00
ANTENNA, 62 DEG, 17.5 dBi,
4.9-5.9 GHz, SECTOR FP
PMP 17.5 5
15.1
14.9
14.2
48-00066-00
ANTENNA, 90 DEG, 16.6 dBi,
4.9-5.9 GHz, SECTOR FP
PMP 16.6 8
17.2
17.3
16.8
48-00048-01
ANTENNA, 360 DEG, 9 dBi, 5 -
6 GHz, OMNI
PMP 9 13 19.4
20.8
20.3
Note
: The RF output power and selection must be professionally programmed and
installed by the manufacturer or a trained professional installer.