PMP Quick Configuration Example
This chapter is provided to aid configuration of point-to-multipoint (PMP) AN-80i
systems. The procedures provided below include steps to setup a basic working
configuration for initial testing, and then to introduce VLAN traffic filtering. No Ethernet
data traffic can be transmitted over the wireless interface before completing this setup.
Figure 28: Web - PMP - Pass-through Only Deployment
Configure Pass-Through Operation
Configure a PMP configuration without VLAN support.
Step I: Create Subscriber Links
1.
Click
New Link
in the main menu to add a subscriber link.
2.
Enter a unique name for this link in the
Link Name
field.
3.
Enter the subscriber MAC address in the
Peer MAC
field.
4.
Refer to the link budget for each subscriber and enter the desired UBR rates in the
Max. DL Burst Rate
and
Max. UL Burst Rate
fields.
5.
Click
Apply
to save and activate settings.
Repeat steps 1 - 5 to add additional links.
Step II: Create Pass-through Group
1.
Click
New Group
in the web page main menu to create a group.
2.
Enter a unique name for this group in the
Group Name
field.
3.
Select Pass-through for the
Group tagging mode
field.
4.
Check the
SC Ethernet Enable
box .
5.
Enter the value 5 for the
Group QoS Level
(0 disables multicast).
6.
Click
Apply
to save and activate the pass through group settings.
Step III: Create Subscriber Connections
1.
Click
New Connection
to add a connection for a subscriber.
2.
Enter a unique name for this connection in the
Connection Name
field.
3.
Select Pass through in the Connection tagging mode field.
4.
Enter the Link ID for this subscriber in the
Parent Link ID
field. Click the
Links List
text to select from the list of links created in step I.