6.2
Procedure to Restore Factory Settings
The AN-80i features a method to gain access to the CLI command prompt for a unit
where the IP address, username, and/or password is unknown. This method requires
local access to the AN-80i PoE power adapter, the ability to power-cycle the AN-80i, a
PC with a telnet client, and an Ethernet cable.
Figure 49: CLI - Recovering Lost IP Address
Use the following steps to gain access to the CLI command prompt:
Power-off the AN-80i PoE adapter. Remove the local network Ethernet cable and
connect your computer directly to the PoE adapter DATA (INPUT) Ethernet port.
Open a command prompt window on the PC and enter the command:
telnet 192.168.25.2
<Do not press Enter key at this time>
1.
Restore power to the AN-80i PoE adapter and wait for 10 seconds.
2.
Power-off the AN-80i PoE adapter for 5 seconds (7 seconds maximum).
3.
Restore power to the AN-80i PoE adapter and wait for approximately 20 seconds.
4.
Press the Enter key on the PC (start the Telnet session). When the login prompt
appears, you have approximately 30 seconds to login using 'admin' as the user
name and 'admin' as password. After login, all AN-80i CLI commands are available.
If the login prompt does not appear, re-enter the Telnet command (up to 60 seconds
from power-on). If this is not successful, repeat steps 2 to 6 using a wait time in step
5 (30 to 40 seconds).
5.
Use the following command to restore the default IP address, username and
password:
save defaultconfig <Enter>
The following parameters are not affected by the 'save defaultconfig' command:
-
System Name, System Location, System Details and Contact
-
Frequency list
-
SNMP configuration
-
ID table (PMP only)
6.
Power-off the PoE adapter and re-connect the network cable. Restore power to the
PoE adapter.