Subscriber Connections and Controls
3.3.1 Ethernet Port (and Cable)
The auto-sensing 10/100Base-T Ethernet port connects through the outdoor Ethernet
cable to a PoE power adaptor/CO switch. The SU-O receives DC power and exchanges
data with the network through this port (straight-through connection).
The SU-O cable access entrance is equipped with a weatherproof seal. The outdoor end
of the Redline supplied outdoor (hardened) CAT-5 Ethernet cable is terminated with an
environmentally sealed RJ-45 connector for connection to the subscriber. The minimum
diameter to pass this connector through a conduit or hole is 26 mm (1 in).
The indoor end of the Redline supplied outdoor (hardened) CAT-5 Ethernet cable is
terminated with a standard indoor RJ-45 connector for connection to a PoE power
adaptor/CO switch. The minimum diameter to pass this connector through a conduit or
hole is 18 mm (11/16 in).
Important -- Warranty Information -- Ethernet Cable
Redline does not endorse or support the use of outdoor cable assemblies: i) not supplied
by Redline, ii) third-party products that do not meet Redline's cable and connector
assembly specifications, or iii) cables not installed and weatherproofed as specified in the
Installation Guidelines manual (70-00068-01-XX). Refer to the Redline Limited Standard
Warranty and RedCare service agreements.
Figure 8: Outdoor Ethernet Cable - Cable Connection
3.3.2 RF
Port
An external RF connector is provided only on the outdoor subscriber with external
antenna (SU-ORF) model. The transceiver RF port (female N-type connector) is used for
sending/receiving the RF signal to/from the antenna. A short coaxial cable is provided to
connect the transceiver to the antenna.
3.3.3 Grounding
Connection
A ground terminal is located on the rear of the subscriber. Use this screw to terminate the
ground wires. Correct grounding is very important for safe operation of wireless
equipment. Ensure that all grounding connections are in accordance with local and
national standards.