Red
MAX
™
Subscriber Modem
SU-O User Manual
70-00057-01-01-DRAFT
Proprietary Redline Communications © 2007
September
7,
2007
Page 37 of 55
4.3.8 modThresh - Modulation Threshold
Use the modulation threshold commands to view and adjust the settings for adaptive
modulation. These setting are made at the factory and should only be adjusted by
experienced personnel. The following table lists all commands available in this mode.
Table 14: CLI - modThresh - Modulation Threshold Commands
Command
Description
reset
Set all parameters to factory default values. Requires confirmation.
set
Change parameter settings.
Rate1Exit
: RW Rate 1 exit threshold. Value > 0
Rate1Entry
: RW Rate 1 entry threshold. Value > Rate1Exit
Rate2Exit
: RW Rate 2 exit threshold. Value > Rate1Entry
Rate2Entry
: RW Rate 2 entry threshold. Value > Rate2Exit
Rate3Exit
: RW Rate 3 exit threshold. Value > Rate2Entry
Rate3Entry
: RW Rate 3 entry threshold. Value > Rate3Exit
Rate4Exit
: RW Rate 4 exit threshold. Value > Rate3Entry
Rate4Entry
: RW Rate 4 entry threshold. Value > Rate4Exit
Rate5Exit
: RW Rate 5 exit threshold. Value > Rate4Entry
Rate5Entry
: RW Rate 5 entry threshold. Value > Rate5Exit
Rate6Exit
: RW Rate 6 exit threshold. Value > Rate5Entry
Rate6Entry
: RW Rate 6 entry threshold. Value > Rate5Exit
show
Display the current setting for all parameters. For example:
Structure --- <<Modulation Rate Threshold Parameters>>
Rate1Exit:..........9.50 dB
Rate1Entry:.........10.50 dB
Rate2Exit:..........12.00 dB
Rate2Entry:.........13.00 dB
Rate3Exit:..........16.50 dB
Rate3Entry:.........17.50 dB
Rate4Exit:..........19.50 dB
Rate4Entry:.........20.50 dB
Rate5Exit:..........23.00 dB
Rate5Entry:.........24.00 dB
Rate6Exit:..........26.00 dB
Rate6Entry:.........27.00 dB