5.4.4 Update Software Procedure
1. Start a telnet session to the subscriber using the following settings:
Login:
admin
Password:
admin
2. Enter the 'loadImage' command. The subscriber will prompt you to enter the
following information:
Server IP address:
[enter address of FTP server]
File
Name:
[enter binary file name- including
.bin
extension]
3. The subscriber performs FTP server authentication with user name 'target' and
password 'secret' (these settings cannot be altered). The image will be uploaded to the
subscriber and saved in the non-volatile memory (flash).
4. The subscriber must be rebooted to load the new software. Enter the 'reboot'
command to reset the unit. The telnet session will be terminated.
Example Download Dialog with Subscriber
Login: admin
Password:
admin, welcome to the SS CLI. (Version 0.3)
SUO#> loadImage
Server IP Address:
[enter ftp server IP address here]
File Name:
[enter binary file name here]
Opening FTP connection.....Done
Downloading image
............................................................................................………………
Done
Programming update........Done
Erasing setup partition. Done.
Writing setup partition. Done.
Erasing boot block. Done
Programming boot block. Done
Flash programming complete.
SUO#>reboot