The SU-O is a fully integrated WiMAX Forum Certified™ subscriber 

unit  incorporating  an  Ethernet  interface  and  wireless  interface  to  a 

WiMAX  base  station.  The  subscriber  is  available  with  integrated 

antenna  or  a  selection  of  external  antennas.  Mounting  options  are 

available to accommodate pole and wall mount. 

3

3

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

P

P

r

r

o

o

c

c

e

e

d

d

u

u

r

r

e

e

 

 

Use  the  steps  outlined  in  the  following  sections  to  assemble  and 

commission the SU-O: 

1.

  Unpack all SU-O components. 

2.

  Install the SU-O equipment, orienting the SU-O (or external 

antenna) in a vertical or horizontal orientation as required. 

3.

  Connect the SU-O to the PoE adapter. 

4.

  Connect the local network device (PC, router, etc) to the PoE. 

5.

  Power-on to configure the SU-O and adjust the antenna as 

required. 

 

Figure 1: SU-OIA System Features 

 

4Gon   www.4Gon.co.uk   info@4gon.co.uk   Tel: +44 (0)1245 808295   Fax: +44 (0)1245 808299

Summary of Contents for SU-O

Page 1: ...70 00067 01 02 Proprietary Redline Comm 2010 Page 1 of 12 October 9 2008 SU O Subscriber Outdoors Quick Install Guide 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 2: ...onally Redline makes no representations or warranties either expressed or implied regarding the contents of this product Redline Communications shall not be liable for any misuse regarding this product The information in this document is subject to change without notice No part of this document shall be deemed to be part of any warranty or contract unless specifically referenced to be part of such...

Page 3: ...It is the user s responsibility to install this device in accordance with the local electrical codes grounding of the transceiver unit mast lead in wire and discharge unit location of discharge unit size of grounding conductors and connection requirements for grounding electrodes Do not place the indoor PoE equipment on or near a direct heat source or operate near water or wet location Do not exce...

Page 4: ...o accommodate pole and wall mount 3 3 I In ns st ta al ll la at ti io on n P Pr ro oc ce ed du ur re e Use the steps outlined in the following sections to assemble and commission the SU O 1 Unpack all SU O components 2 Install the SU O equipment orienting the SU O or external antenna in a vertical or horizontal orientation as required 3 Connect the SU O to the PoE adapter 4 Connect the local netwo...

Page 5: ...optional Figure 2 SU ORF System Features 3 2 Install the SU O Mounting procedures are dependent on the type of SU O integrated or external antenna For detailed information refer to the Subscriber Installation Guidelines 70 00068 01 on the documentation CD ROM supplied with the base station 3 3 Connect Outdoor Cable to SU O The outdoor end of the Ethernet cable supplied by Redline is terminated wit...

Page 6: ...able SU O Cable Connection The weatherproof connector must be finger tight plus 1 16th turn only Choose a tool suitable to avoid damaging the plastic connector The minimum diameter to pass the outdoor connector through a conduit or hole is 26 mm 1 in 3 4 Connect the SU O to the PoE Adapter The indoor end of this cable is terminated with a standard indoor RJ 45 connector for connection to the indoo...

Page 7: ...p PC router or other supported network device Figure 5 SU O Power and Network Connections PoE Power Adapter Caution Warning to Service Personnel 48 VDC Connecting customer premises Ethernet equipment directly to the Data and Power Out connector on the SU O Power over Ethernet power adapter may damage customer network interface equipment Customer equipment including personal computers routers etc m...

Page 8: ...eived signal and you may be unable to connect to any base station The SU O must be mounted and connected to the Ethernet PoE adapter before the antenna alignment can be completed The alignment must be performed in both the azimuth and elevation planes When possible obtain accurate antenna pointing azimuth and elevation angles for each installation site Base Station Location For each SU O installat...

Page 9: ...nnect a PC to the DATA IN port of the PoE power injector 2 Start a telnet session and login to the SU O The factory default login parameters are IP Address 192 168 101 1 Username admin Password admin 3 Enter the case sensitive command to enable the audible signal set boardConfig Buzzer 1 The SU O should now be emitting an audible signal that varies with the received signal strength A faster repeti...

Page 10: ...en interference is present The SNR and RfRssi readings are available on the Telnet interface of the subscriber station Use the monitor mode to provide a dynamically updated display of the RSSI and other subscriber statistics From the root CLI mode enter the following command to activate the monitor display monitor ENTER When monitor mode is active the screen is updated continuously with the latest...

Page 11: ...e highest achieved RfRssi reading Once the alignment sweep has been completed the RfRssi value should be checked against the estimated value obtained from the link budget For a LOS link the measured RfRssi should be within five dBm of the calculated value A lower reading may indicate that the antenna is aligned to a sidelobe If the RfRssi is much lower than the calculated value this may indicate a...

Page 12: ...70 00067 01 02 Proprietary Redline Comm 2010 Page 12 of 12 October 9 2008 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Reviews: