background image

Caution On use

• Never short-circuit the battery pack terminals.
• Never attempt to open the battery pack.
• Avoid mechanical shock.
• Please consult the store where you purchased this battery pack or your 
sales representative before using the battery pack in a product whose 
Operation Manual/Operating Instructions does not explicitly state that 
the  battery  pack  can  be  used,  or  before  using  the  battery  pack  in 
conjunction with another power supply. In appropriate use of the battery 
pack may result in unit misoperation.
•  The  internal  impedance  of  the  battery  pack  increases  as  the 
temperature drops to 5°C (41°F) or below. This may result in a shorter 
operating time or the failure of the component to which it is connected to 
turn on. This phenomenon occurs more frequently in battery packs that 
have been charged many times than in new ones.
• The performance and operating time of the battery may drop under cold 
conditions. When this happens, do the following to extend the operating 
time of the battery pack:
- Keep the battery pack warm and attach it to the component right before 
use.
- Charge the battery pack only with the charger dedicated to the RP-
BP975  Battery  Pack  like  REDPRO  Model  RP-DC20,  and  within  a 
temperature range of 10°C to 30°C (50°F to 86°F).
• Large discharge amount may expedite deterioration of battery pack’s 
internal cells. To prevent this, use the RP-BP975 with discharger amount 
of about 3 A or less.
•  The  maximum  discharge  amount  is  5A  for  the  RP-BP975  at  23°C 
(73°F). Continuous use at levels beyond the maximum discharge level 
may  cause  the  protection  circuit  to  shut  off  the  current  to  protect  the 
internal cells.
• A protection circuit will shut off the current to protect the battery pack’s 
internal cells under the following conditions: 

To the purchasers of the RP-BP975

The RP-BP975 Lithium-Ion Battery Pack has a rated capacity of less 
than 100 Wh. It can thus be transported as a non-hazardous lithium-ion 
battery. Related laws and regulations are, however, subject to change. 
For detailed conditions regarding the transport of battery packs, please 
consult your respective air transport company.
-When  an  excessive  current  flow  is  caused  by  overloading  or  short 
circuited terminals
- When the voltage drops to 5V or lower and results in the cessation of 
current output.
• Once the protection circuit has tripped, the battery pack will  not return 
to normal automatically. To cancel the effect of the protection circuit, you 
must charge the battery pack with charger dedicated to the lithium-ion 
battery packs like REDPRO model RP-DC20.

Caution On storage

• Never expose the battery pack to rain or moisture.
• Keep away from children.
• Never expose the battery pack to temperatures above 60°C (140°F). 
Store the battery pack in dry place at temperatures between 0°C to 23°C 
(32°F to 73°F).
• If the battery pack is to be stored for a short period (approximately more 
than 24 hours and a month or less), discharge the battery pack to 90% of 
its full capacity to prevent deterioration of battery pack’s internal cells.
• When storing the battery pack for an extended period (more than a 
month),  

it is recommended that you discharge the battery pack to about 50% of 
its full capacity. (The two LED light up green) While the battery pack is 
stored, charge it until the capacity reaches 50% once in 6 months.
• If the battery pack terminals become soiled, clean them with a soft 
cloth.

WARNING

• Batteries shall not be exposed to excessive heat such as sunshine. 
fire or the like.

Battery life

• Battery life may be shortened due to storage or operation in high 
temperatures, storage with its full capacity, and frequent use.
• Renew the battery pack when the operating time with a completely 
charged battery pack becomes noticeably short or all LEDs flash green 
because the self-diagnostics function has detected the end of battery 
life. If a battery pack is deteriorated, all LEDs may not light when the 
CHECK button is pressed just after charging is completed.

Self-diagnostic function

When an abnormality is detected, all the LEDs flash in green. If 
this happens, stop using the battery pack immediately. Once the 
LEDs start flashing, the battery pack cannot be recharged

SPECIFICATION

Battery type:   

 Lithium-Ion Rechargeable Battery

Maximum voltage: 

 8.2 V DC

Nominal voltage: 

 7.4 V DC

Capacity RP-BP975: 

 48.80 Wh / 6600 mAh 

 

Charging time: 

 approx. 240 minutes

Operating temperature: 

–20°C to +45°C (–4°F to +113°F)

Dimensions (w/h/d) 

 70 × 61 × 40 mm

RP-BP975

Battery Pack Operating Instructions

Before  operating  the  unit,  please  read  this  manual  thoroughly  and 
retain it for future reference.

Important Safety Instructions

• Keep these instructions.
• Heed all warnings. 
• Follow all instructions.
• Do not use this apparatus near water. 
• Clean only with dry cloth.
• Do not install near any heat sources such as radiators, heat registers, 
stoves, or other apparatus (including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type 
plug. A polarized plug has two blades with one wider than the other. A 
grounding-type plug has two blades and a third grounding prong. The 
wide  blade  or  the  third  prong  are  provided  for  your  safety.  If  the 
provided plug does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.
• Only use attachments/accessories specified by the manufacturer. 
Use only with the cart, stand, tripod, bracket, or table specified by the 
manufacturer, or sold with the apparatus. When a cart is used, use 
caution when moving the cart/apparatus combination to avoid injury 
from tip-over.
• Unplug this apparatus during lightning storms or when unused for 
long periods of time.
•  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is 
required when the apparatus has been damaged in any way, such as 
plug is damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

Overview/Features

The RP-BP975 Battery Pack uses Lithium-Ion Batteries. 
Use  the  RP-BP975  Battery  Pack  only  with  equipment  whose 
Operation Manual/Operating Instructions recommends its use.

The features of the RP-BP975 are as follows:

• The battery pack can be recharged before being fully exhausted.
• Remaining capacity is indicated by a four-step LED display 
(more than 80%, 60%, 40%, 20%) when you press the Check  button.
• Remaining capacity is indicated on LED display when you press the 
Check button.

Caution On charging

• The battery pack can be charged within a temperature range of 0°C 
to 40°C (32°F to 104°F). However, we recommend charging within a 
temperature range of 10°C to 30°C (50°F to 86°F) to ensure optimum 
battery performance. 

Or to use REDPRO Charger RP-DC20 with 

Charger plate model RP-CF915 to charge this Battery Pack.

• The battery pack discharges naturally over time. To prolong the life of 
the product, it is recommended that you fully charge the battery pack 
with RP-DC20 charger, before using it. For details on the charging 
procedure,  refer  to  the  Operation  Manual/Operating  Instructions 
supplied with the battery charger.
• The battery pack may become warm in use or while being charged.  
This is normal.

If you want to know more about REDPRO Products please visit our 

website:  

www.red-pro.com

Reviews: