WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A
SUITABLY QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS UNIT WHERE IT MAY BE SUBJECTED TO
FREEZING CONDITIONS.
The Powerstream-Eco is recommended to supply a
MAXIMUM
of two washbasins (see diagram 1a)
OR
a washbasin and shower (see diagram 4b)
If the Powerstream-Eco is connected to a mixer tap
then only
NON-
Thermostatic types should be used
(water mixes at the outlet pipe only).
The Powerstream-Eco is
NOT
to be fitted to a
bath or kitchen sink other than for hand-washing purposes.
(See Guarantee exclusions on page 16 and
product flow rate tables on page 14).
The unit
MUST NOT
be mounted upside down (diagram 1b).
BEFORE YOU START
Check that the mains electric is capable of supplying the required current.
See the rating plate for current requirements.
Check the pressure of the main water supply.
To operate correctly, the unit requires the following running pressures.
Check the rating plate to see which applies:-
Model
Dynamic Water Pressure
Basin
Shower
Minimum
Maximum
Minimum
Maximum
Up to 9.5kW
10 psi (0.7 bar)
(69 kPa)
150 psi (10.3 bar)
(1035 kPa)
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
Up to 10.8kW
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
20 psi (1.4 bar)
(138 kPa)
150 psi (10.3 bar)
(1035 kPa)
HOW TO INSTALL YOUR
POWERSTREAM-ECO
Diagram 1a
Examples of fitted units
Diagram 1b
Acceptable unit orientation