1.4 - Menu Options
The set-up menu should be configured as follows, some of these parameters will be modified by instructions in
the previous sections.
Option
Setting
02
80
o
C
or as required 21-80
o
C
03
30
o
C
or as required 21
o
C- maximum temperature set
04
1
if operating from a switched live or if a room
thermostat installed 0 if not
.
(
Never
select 2)
05
1
if option 4 set to 1
06
1
recommended (unless instructed otherwise)
07
0
mandatory
11
1
min or user defined 1-6
minutes delay in switching
elements.
12
0
mandatory
13
0
mandatory
14
n/a
15
0
mandatory
16
1
for 12k
W
boiler operation
for reduced maximum output power see § 2.7.1
17 à 22
n/a
23
0
mandatory
Notes: In normal operation press the + button to check if the room thermostat is calling for heat once, a 1 indicates a call for heat. Press
the + button a second time and if auto-adaptability has been selected the temperature correction applied will be displayed (Option
06 Auto-adaptability adjusts the temperature of the heating circuit for the most efficient and temperature stable operation. )