Remove the four cover screws and lift the
cover off.
Remove the four inlet cover screws and remove
inlet cover - also the two side access trimplate
section screws and remove complete with seal
(See diagram 1).
Hold the shower vertically against the wall and
mark the top hole first.
Drill the hole to take the rawl plug provided
(taking care to keep dust away from the
shower)
.
Put the top screw in first leaving it proud by
5mm approximately. The shower can now be
hung on this screw.
Position the shower so that it is vertical then
mark and drill the other two holes. Then fix the
Shower to the wall.
Assemble the accessories as shown in
Diagrams 27 and 28. Fix the riser rail with
screws provided. The fixing holes are revealed
by removing the plastic fronts.
Note:
Care must be taken to ensure the notch
in the riser rail is
fully engaged
into the
corresponding lug in the wall bracket. This has
been made a
firm fit
to aid stability and stop
rotation.
Having determined the direction of the inlet
water mains supply and cable approach for
the installation (Top, Bottom, or Rear or any
combination) - it is necessary to remove the
appropriate section inserts. See
Plumbing
Connections
and
Electrical Installation
sections (Pages 5 and 7) for detailed guidance.
480
1000
Handset Height Adjustment
Drop-down rail on side wall
Alarm Pull Cord
Back
Rest
Elevation
650
1500x1500 Wheelchair Turning Space
Towel / Grab Rail
Floor
Drain
T
ip Up Seat
Shower Curtain
1200
1200
500
350
Drop-down
Rail
850
300
2000
Shower Riser
Rail
Fall of Floor
Plan
Shower
Unit
All measurements shown are in millimetres. Drawing sizes are
not to scale. Shower model shown is a Selectronic Premier Plus.
Typical guideline dimensions used for
less- abled bathroom installations