4
Do not use excessive force when making
the connection to the unit.
WARNING:
TAKE CARE TO AVOID RESTRICTING
THE OUTLET OF THE PRESSURE RELIEF
DEVICE.
Section 5 Electrical
Connection
A means of disconnection in all poles must
be incorporated in the fixed wiring in
accordance with the wiring rules.
THIS HANDWASH MUST BE
EARTHED.
The electrical installation must be in accordance
with the current BS.7671 (IET Wiring
Regulations) and ‘Part P’ of the Building
Regulations and/or local regulations
1.
Turn off Electricity at isolation switch.
2.
The handwash unit is designed for a single
phase AC electrical supply.
3.
Use 3-Core 1.5mm² double insulated cable.
The cable can be surface clipped, hidden or via
conduit.
4.
The incoming cable access to the
handwash unit is located at the top,
bottom or rear of the unit on the right
hand side.
5.
Cut back cable.
6.
Connect cable to terminal block making
sure that all the retaining screws are
VERY TIGHT and that no cable insulation
is trapped under the screws.
7.
Ensure the cable clamp is used to secure
the cable into position.
WARNING:
FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN
FAILURE OF THE TERMINAL BLOCK
Section 6 Fitting
The Sw ivel Arm
Into Position
IMPORTANT: Fitting the swivel arm must
precede fitting the front cover
1.
Push the swivel arm into the outlet and
tighten by turning clockwise until swivel arm is
tight.