background image

* When ordering, please refer to the Figure3-1, 3-2 below and select C7100A-0x with IO Modules.

* All IO modules are shipped after installation in the enclosure.

* Afterwards, if the customer wants to mount the new modules ordered separately, remove the already

installed module from the enclosure first, and check for foreign substances on the surface that the IO Module

touches and wipe clean with a soft cloth using alcohol. Then, complete the installation by tightening the

included hexagon bolts. (Please perform the 2.2. Performance Test after installation.)

3.2. Example of ordering

This is an example of how customers order the RWC7100A with IO Modules. For more information, please contact our

sales or distributor before placing an order.

Use case

Module Type

Order code

Type B (Left side)

Type A (Right side)

Blank Modules

C7100A-0x

5600-1000

2 x 5600-2000

RF Modules

C7100A-0x

5600-1000

5600-2000

5630-1000 or 5630-2000

RF, D-Sub and USB
Interface

C7100A-0x

5630-1000 or 5630-2000

5640-1000

5640-1100 (Select if necessary)

5640-2000

RF, D-Sub,USB and
Wide-band
Circular Antenna

C7100A-0x

5630-1000 or 5630-2000

5640-1000

5640-1100 (Select if necessary)

5640-2000

O7100A-92 or O7100A-93

RedwoodComm Co., Ltd.  |

RWC7100A Operation Manual

Page 14 of 16

Summary of Contents for RWC7100A

Page 1: ...RWC7100A RF SHIELDING ENCLOSURE Operation Manual R211216_1 10...

Page 2: ...mance Test 7 2 2 1 How to Set up the Equipment Required for RF Shielding Effectiveness Test 7 2 2 2 Test Procedure 8 2 2 3 An Example Test Result of RF Shielding Effectiveness 9 2 3 Maintenance 10 2 3...

Page 3: ...nished or recommended by RedwoodComm causes problems or damage that is attached to or used in connection with the product Where any additional parts equipment that is not authorized by RedwoodComm was...

Page 4: ...customization panel To maintain lasting shielding effectiveness users can order additional EMI gaskets and easily replace them when necessary There are many kinds of wireless standards in various ind...

Page 5: ...effectiveness please refer to the 2 3 Maintenance Dimensions and Weight Dimensions W x D x H mm inches Interior workspace 260 x 190 x 100 10 2 x 7 5 x 3 9 Exterior 355 x 270 x 185 14 0 x 10 6 x 7 3 We...

Page 6: ...tdoor and where the ground is not flat If this product is not used for a long time store it in a dry place away from direct sunlight covered with vinyl or placed in a cardboard box If this product is...

Page 7: ...oor from the top 4 x M3 Hole DP 8mm Mounting position for RWC8201A only EMI Mesh Gasket This detachable part is for obtaining optimal RF shielding 2set x EMI Foam Gasket This detachable part is for ob...

Page 8: ...capable of generating 400M 6400MHz tone signal Signal generator side antenna omni directional one Signal power meter A spectrum analyzer or equivalent device that can measure the tone power of a signa...

Page 9: ...gnal generator or RWC1020A as follows Frequency 400 1MHz Power 10dBm 5 Open the RWC7100A door and measure the power Pref moving the reference antenna to several points as shown in Figure 2 3 Figure 2...

Page 10: ...RF Shielding Effectiveness The product conformity test was measured using a method modified from the IEEE STD 299 1 standard Figure 2 5 Shielding effectiveness of RWC7100A RedwoodComm Co Ltd RWC7100A...

Page 11: ...rosion or oxidation progresses on the surface that the gasket touches on the door or on the gasket frame Clean thoroughly with alcohol and a soft cloth It must be kept clean at all times Typically the...

Page 12: ...of the 1st Mesh Gasket place the seam in the center and insert it slowly with an even density 5 In the case of the 2nd and 3rd Foam Gasket refer to the picture above remove the tape on the back of the...

Page 13: ...Set RWC8201A mounted on the lid of RWC7100A Antenna Dimensions W x D x H mm 130 x 130 x 15 Frequency Range 700MHz to 8 5GHz N F to SMA F Adaptor and RF cables installed O7100A 92 O7100A 93 Figure 3 1...

Page 14: ...use shielded cables to ensure shielding effectiveness 5630 2000 D Sub 9Pin Module Type B Outside dimensions W x D x H mm 102 x 80 x 24 DB 9P M outside to DB 9S F inside 5 000pF Pi Filter Unused ports...

Page 15: ...rformance Test after installation 3 2 Example of ordering This is an example of how customers order the RWC7100A with IO Modules For more information please contact our sales or distributor before pla...

Page 16: ...the RWC8201A antenna is measured not only in the 400 MHz band but also in the 900 MHz band Especially transfer function between antennas in the 400 510 MHz and 860 960 MHz bands are dealt with in det...

Page 17: ...RWC8201A antennas is about 40dB and starting decreasing from 490MHz it becomes 27dB at 510MHz In the 900MHz band which is within the recommended frequency range of RWC8201A antenna the path loss is ab...

Page 18: ...A 2 DB9 Module Pin map Fig A 4 DB9 Module Pin Map RedwoodComm Co Ltd RWC7100A Operation Manual Page 17 of 16...

Reviews: