5.4 BSB612 & BSB615 & BSB618
5.4 BSB612 & BSB615 & BSB618
1. Power Input AC: 3 phase input, 110V–240V/50-60Hz. It is also ok to connect only single phase to the device
such as L1-N connection only.
AC Power supply use L1-N only. Phase 2-3 connections are used to BPL signal transmission.
2. Power LED: Turns ON when there is power in device.
6. Ethernet Cables, SFP Module Options
6. Ethernet Cables, SFP Module Options
BSB Series Industrial Unmanaged Ethernet Switches have standard Ethernet ports. According to the link type, the
switches use CAT 3, 4, 5, 5e UTP cables to connect to any other network device (PCs, servers, switches, routers, or
hubs).
6.1 Cable Type and Specifications
6.1 Cable Type and Specifications
Cable
Cable
Type
Type
Max. Length
Max. Length
Connector
Connector
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
6.2 ETH Cable Pin Assignments
6.2 ETH Cable Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 - 2 are used for transmitting data and pins 3 - 6 are used for receiving data.