background image

7. SFP Types

7. SFP Types

The small form-factor pluggable (SFP) is a compact, hot-pluggable network interface module used for both
telecommunication and data communications applications. An SFP interface on networking hardware is a modular slot
for a media-specific transceiver in order to connect a fiber-optic cable or sometimes a copper cable.

The advantage of using SFPs compared to fixed interfaces (e.g. modular connectors in Ethernet switches) is that
individual ports can be equipped with any suitable type of transceiver as needed.

7.1 100Mbit/s SFP

7.1 100Mbit/s SFP

- Multi-mode fiber, LC connector, with black or Beige color coding

SX – 850 nm, for a maximum of 550 m

- Multi-mode fiber, LC connector, with blue color coding

FS  – 1300 nm, for a distance up to 5 km.

LFX (name dependent on manufacturer) – 1310 nm, for a distance up to 5 km.

Available SFP module from REDZ:

Model Name

Model Name

Description

Description

Cable Used

Cable Used

CE-GLC-FE-100FX

155M, Dual Fiber, Multi

Mode, 1310nm, 2KM,
Industrial

LC-LC MM Duplex

- Single-mode fiber, LC connector, with blue color coding

LX – 1310 nm, for distances up to 20 km

Available SFP module from REDZ:

Model Name

Model Name

Description

Description

Cable Used

Cable Used

CE-GLC-FE-100LX

155M, Dual Fiber, SM,

1310nm, 20KM, Industrial

LC-LC SM Duplex

EX – 1310 nm, for distances up to 40 km

- Single-mode fiber, LC connector, with green color coding

ZX – 1550 nm, for distances up to 80 km, (depending on fiber path loss)

EZX – 1550 nm, for distances up to 160 km (depending on fiber path loss)

- Single-mode fiber, LC connector, Bi-Directional, with blue and yellow color coding

BX (officially BX10) – 1550 nm/1310 nm, Single Fiber Bi-Directional 100 Mbit SFP Transceivers, paired as BX-U (blue) and
BX-D (yellow) for uplink and downlink respectively, also for distances up to 10 km. Variations of bidirectional SFPs are
also manufactured which higher transmit power versions with link length capabilities up to 40 km.

Available SFP module from REDZ:

Model Name

Model Name

Description

Description

Cable Used

Cable Used

GLC-BX-20U

155M Bidi SFP, 1310nm-

TX/1550nm-RX, 20km, LC
Port, Industrial

LC-LC SM Simplex

GLC-BX-20D

155M Bidi SFP, 1550nm-

TX/1310nm-RX, 20km, LC
Port, Industrial

LC-LC SM Simplex

- Copper twisted-pair cabling, 8P8C (RJ-45) connector

100BASE-TX – for distances up to 100m.

Available SFP module from REDZ:

Model Name

Model Name

Description

Description

Cable Used

Cable Used

Summary of Contents for BSB Series

Page 1: ... IP standard over Low Voltage power lines and allows easy connection between TCP IP based terminals without use of extra cables BSB Series has models also with SFP ports for Fiber connectivity BSB Series with SFP ports offers fiber and ethernet connectivity in same device with plug and play SFP ports Wide range of SFP modules are available to be used with BSB series BSB Series has models also with...

Page 2: ...1000 SFP Ports Plug and play without additional settings AC or DC wide range power options Wide operating temperature range from 25 to 70 C AC and 40 to 85 C DC power input versions Rugged Metal IP 40 housing design DIN Rail mounting 2 4 Features for Models with PoE Ports Supports 8 x 10 100Base T X ports Supports PoE on all ports 90 Watt Power Supply combined for all ports Maximum 36 Watt per por...

Page 3: ... Din Rail kit on rear panel The Din Rail kit helps switch to fix on the Din Rail Slant the switch and mount the metal spring to Din Rail Then Push the switch toward the Din Rail until you heard a click sound 4 Front Panel Description 4 1 BSB115 BSB215 ...

Page 4: ...rt 5 4 ETHERNET Activity LED for port 5 Blinks during ethernet activity 4 2 BSB118 BSB218 1 10 100Base T X Ethernet ports 1 2 3 and 4 2 ETHERNET Activity LEDs for port 1 2 3 and 4 Blinks during ethernet activity 3 ETHERNET Activity LEDs for port 5 6 7 and 8 Blinks during ethernet activity 4 10 100Base T X Ethernet ports 5 6 7 and 8 4 3 BSB120 BSB220 ...

Page 5: ... for SFP Ports 1 and 2 There are 2 LEDs for each port One Blinks during ethernet activity and one is steady when speed is Gigabit 4 10 100Base T X Ethernet ports 5 6 7 and 8 5 10 100 1000 SFP Ports 1 and 2 4 4 BSB268 1 10 100Base T X Ethernet ports 1 2 3 and 4 Supports PoE on all ports 90 Watt Power Supply combined for all ports Maximum 36 Watt per port ...

Page 6: ... Maximum 36 Watt per port 4 5 BSB612 1 10 100Base T X Ethernet port 2 BPL Activity LED Blinks during BPL Ethernet activity 3 BPL Link LED LED Turns ON if the link can be established 4 Master Indication LED LED Turns ON if the device is started as Master device 5 Switch position to select the device as Master or Slave Device must be repowered after changing the setting to take into effect 4 6 BSB61...

Page 7: ...LED LED Turns ON if the link can be established 5 Master Indication LED LED Turns ON if the device is started as Master device 6 Switch position to select the device as Master or Slave Device must be repowered after changing the setting to take into effect 4 7 BSB618 1 10 100Base T X Ethernet ports 1 2 3 and 4 2 ETHERNET Activity LEDs for port 1 2 3 and 4 Blinks during ethernet activity ...

Page 8: ...on LED LED Turns ON if the device is started as Master device 8 Switch position to select the device as Master or Slave Device must be repowered after changing the setting to take into effect 5 Top Panel Description 5 1 BSB115 BSB118 BSB120 1 Power Input DC 5 60V DC Polarity protected so that the power input can be connected in any direction 2 Power LED Turns ON when there is power in device 3 Res...

Page 9: ...z to 63Hz AC input 2 Power LED Turns ON when there is power in device 3 Reset Button Reset the device 5 3 BSB268 1 Power Input AC 100 240V AC 120 370V DC 50Hz to 60Hz AC Wide Range Power Input 90Watt Power Supply 2 Reset Button Reset the device ...

Page 10: ...ns BSB Series Industrial Unmanaged Ethernet Switches have standard Ethernet ports According to the link type the switches use CAT 3 4 5 5e UTP cables to connect to any other network device PCs servers switches routers or hubs 6 1 Cable Type and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 6 2 ET...

Page 11: ...ndustrial 100Mbit s SFP Single mode fiber LC connector Bi Directional with blue and yellow color coding BX officially BX10 1550 nm 1310 nm Single Fiber Bi Directional 100 Mbit SFP Transceivers paired as BX U blue and BX D yellow for uplink and downlink respectively also for distances up to 20 km Variations of bidirectional SFPs are also manufactured which higher transmit power versions with link l...

Page 12: ...P CE GLC BX 10U 1 25G Bidi SFP 1550nm TX 1310nm RX 10km LC or SC Port Industrial 1Gbit s SFP CE GLC BX 10D 1 25G Bidi SFP 1550nm TX 1310nm RX 10km LC or SC Port Industrial 1Gbit s SFP CE GLC BX 20U 1 25G Bidi SFP 1310nm TX 1550nm RX 20km LC or SC Port Industrial 1Gbit s SFP CE GLC BX 20D 1 25G Bidi SFP 1550nm TX 1310nm RX 20km LC or SC Port Industrial 1Gbit s SFP CE GLC BX 40U 1 25G Bidi SFP 1310n...

Page 13: ...1 25 Gbit s gigabit Ethernet Other multi mode SFP applications support even higher rates at shorter distances Connect 2 x same device on both device LC LC SM Duplex NOTE Multi Mode Duplex should connect same Multi Mode Duplex wavelength like 850MM should connector MM 850nm couldn t connect MM 1310 Single Mode duplex should connect same Single Mode wavelength SM Duplex 1310 should connect SM 1310 D...

Page 14: ...X 1310 nm for distances up to 20 km Available SFP module from REDZ Model Name Description Cable Used CE GLC FE 100LX 155M Dual Fiber SM 1310nm 20KM Industrial LC LC SM Duplex EX 1310 nm for distances up to 40 km Single mode fiber LC connector with green color coding ZX 1550 nm for distances up to 80 km depending on fiber path loss EZX 1550 nm for distances up to 160 km depending on fiber path loss...

Page 15: ... 1 25G Dual Fiber 1310nm 10km Industrial LC LC SM Duplex GLC LH SMD 20 1 25G Dual Fiber 1310nm 20km Industrial LC LC SM Duplex EX 1310 nm for distances up to 40 km ZX 1550 nm for distances up to 80 km depending on fiber path loss with green extraction lever see GLC ZX SM1 EZX 1550 nm for distances up to 160 km depending on fiber path loss BX officially BX10 1490 nm 1310 nm Single Fiber Bi Directio...

Page 16: ...km and 120 km 1 Gbit s for copper twisted pair cabling 8P8C RJ 45 connector 1000BASE T these modules incorporate significant interface circuitry for Physical Coding Sublayer recoding and can be used only for gigabit Ethernet because of the specific line code They are not compatible with or rather do not have equivalents for Fiber Channel Unlike non SFP copper 1000BASE T ports integrated into most ...

Page 17: ...8 2 Connection Diagram for ETH Versions 8 3 Connection Diagram for SFP Port Versions ...

Page 18: ...Based System BPL Link Based System Media CAT5 Power Line Bandwidth 100Mbps Up to 30Mbps Re Wire Yes No Using existing Power Line Span 100m 600m Multiple Nodes N A Up to 10 hops 1000 nodes Encryption Yes but difficult to configure Yes Plug Play Installment Difficult Easy simply user power line ...

Page 19: ...upport PoE 100 240V AC 120 370V DC 50Hz to 60Hz AC Wide Range Power Input 90 Watt Power Supply combined for all ports BSB612 Industrial Unmanaged Ethernet Switch 1 x 10 100 T x ETH ports 1 x BPL Broadband Power Line Link 3 Phase AC Power Input 110V 240V 50 60Hz BSB615 Industrial Unmanaged Ethernet Switch 4 x 10 100 T x ETH ports 1 x BPL Broadband Power Line Link 3 Phase AC Power Input 110V 240V 50...

Reviews: