29
PROBLEM: The walking belt is off-center
SOLUTION:
a. If the walking belt has shifted to the left, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn the left rear roller adjustment
bolt clockwise, and the right bolt counterclockwise,
1/4 of a turn each. Be careful not to overtighten the
walking belt. Plug in the power cord, insert the key
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
b. If the walking belt has shifted to the right, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn the left rear roller adjustment
bolt counterclockwise, and the right bolt clockwise,
1/4 of a turn each. Be careful not to overtighten the
walking belt. Plug in the power cord, insert the key
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
PROBLEM: The walking belt slips when walked on
SOLUTION:
a. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn both rear roller adjustment
bolts clockwise, 1/4 of a turn. When the walking belt
is correctly tightened, you should be able to lift each
side of the walking belt 3 to 4 inches off the walking
platform. Be careful to keep the walking belt centered.
Plug in the power cord, insert the key and carefully
walk on the treadmill for a few minutes. Repeat until
the walking belt is properly tightened.
PROBLEM: The heart rate monitor does not function properly
a. If the heart rate monitor does not function properly, refer to HEART RATE MONITOR TROUBLE-
SHOOTING on page 7.
b. If the heart rate monitor still does not function properly, the battery
should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the ÒopenÓ position. Remove
the cover.
Next, remove the old battery from the sensor unit. Insert a new
CR
2032 battery
, making sure that the writing is on top. In addition, make
sure that the rubber gasket is in place in the sensor unit. Replace the
battery cover and turn it to the closed position.
b
a
a
CR2032
Battery
Rubber
Gasket