background image

HIDEAWAY

ACTIVE SENSOR-FLUSH URINAL

Plumbers, please ensure a copy of the installation 
instructions is left with the end user for future reference

HIDEAWAY

 

ACTIVE SENSOR-FLUSH URINAL

 

 

 

12.0 

Maintenance of the Solenoid Cartridge: 

 

When performing maintenance on the flush valve or its components shut off the power and water supply and unplug 

the solenoid sealed connector cable. 

 

1)  Unscrew the solenoid cartridge (if required use a 17mm socket). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)  Rinse and clean the strainer fitted to the solenoid cartridge. 

 

 

 

 

 

3)  Before re-installing the solenoid cartridge lubricate the two O-Rings  

with a suitable tap O-Ring lubricant, Hydroseal tap lubricant or equivalent. 

 

 

 

Note: Do not over-tighten.  The max torque is 1Nm (hand-tight). 

 

 

 

 

 

 

 

 

 

 

13.0 

Spare parts 

 

 

 

 

9503303 HIDEAWAY URINAL CONTROL UNIT 240V 
9503304 HIDEAWAY URINAL SENSOR TRAP (NO SEALS) 
9503305 HIDEAWAY URINAL 240V TRANSFORMER 
9503306 HIDEAWAY URINAL SENSOR EXT CABLE (2.65M) 
9503307 HIDEAWAY URINAL INLET & OUTLET  SEAL 
9503308 HIDEAWAY URINAL SHUTOFF VALVE 
9503309 HIDEAWAY URINAL SOLENOID  CARTRIDGE 
9503310 HIDEAWAY URINAL SOLENOID  BODY 
9503311 HIDEAWAY URINAL AIR-BREAK 
9503984 HIDEAWAY URINAL CONTROL BATTERY POW ERED (LESS BATTERY) 
9503985 HIDEAWAY URINAL BATTERY 6V CR-P2 

 

17mm socket 

Sealed connector

 cable 

 

O-Rings

 

 

Strainer 

 

page 15 of 16

Summary of Contents for HIDEAWAY

Page 1: ...ions or queries during installation please contact Tech Support for phone assistance free call 07 3875 2465 We are happy to assist you Dear Customer This is the warranty by Reece Pty Ltd relating to t...

Page 2: ...d valve is fitted with 200mm cable and 2 pin connector Fig 1 Cables are supplied as follows Sensor extension cable 2500mm long with female male 4 pin connectors 1800mm power cable wired with single ma...

Page 3: ...mum size not supplied free of kinks for sensor extension cable Fig 4 7 Fit single 240 volt 10 amp GPO for transformer power supply unit adjacent to proposed location of controller 3 0 Control Unit Con...

Page 4: ...V flush with finished wall Fig 7 5 Fit kee seal to waste trap and lubricate before gently pushing into 50mm PVC DWV pipe so trap finishes flush with face of wall Fix waste trap to wall with single scr...

Page 5: ...r C Do not press buttons on the controller yet LED FLASH RESPONSE FIRST TIME POWER ON MEANING 1 Initial 2 short ashes followed by steady flashes at 1 second intervals After about 25 seconds of steady...

Page 6: ...ns in the male plug are not bent apart and line up with the holes in the female plug If required use your fingers to squeeze the plug and pins together 3 Check plug alignment and re connect Re connect...

Page 7: ...Schools This program will ush the urinal only after every 3 rd user or 15 minutes after use whichever comes rst It also triggers a janitor s ush after 48 hours of non use Button 2 To change the progr...

Page 8: ...onnection Now the ushing is suspended for 30 minutes 3 Add more of the cleaning agent to the water of the urinal After 30 minutes a ush will automatically trigger and the urinal is ready for use How t...

Page 9: ...instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Use the following figures to provide installation guidance Fig 11 In ceiling ins...

Page 10: ...NSOR FLUSH URINAL Plumbers please ensure a copy of the installation instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig...

Page 11: ...HIDEAWAY ACTIVE SENSOR FLUSH URINAL HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig 13 page 11 of 16...

Page 12: ...ically switch to Saver Mode 1 flush every minute when 4 users visit the urinal in less than 1 minute intervals no matter how many times used 1 minute of non use will reset the control unit back to Nor...

Page 13: ...sioning Look for 2 confirmation flushes to confirm urinal is functioning normally Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance 5 seconds pause Pause then Temperature Se...

Page 14: ...ge is blocked Dynamic pressure has changed Un screw the solenoid cartridge and rinse out dirt out of the strainer see Section 1 Maintenance of the Solenoid Cartridge Check dynamic pressure and reset f...

Page 15: ...enoid cartridge lubricate the two O Rings with a suitable tap O Ring lubricant Hydroseal tap lubricant or equivalent Note Do not over tighten The max torque is 1Nm hand tight 13 0 Spare parts 9503303...

Page 16: ...RINAL INLET OUTLET SEAL 200 034 9503309 HIDEAWAY URINAL SOLENOID CARTRIDGE 200 036 9503310 HIDEAWAY URINAL SOLENOID BODY 200 037 9503311 HIDEAWAY URINAL AIR BREAK 200 038 9503312 HIDEAWAY URINAL FLUSH...