background image

METHVEN

AURAJET AIO RAIL SHOWER

CLEANING RECOMMENDATIONS

We recommend the use of soapy water or approved cleaners. This 
product should not be cleaned with abrasive materials. Damage caused 
by improper treatment is not covered by the product warranty – refer to 
warranty conditions on the last page.

To see the complete Aio range go to 

 

www.reece.com.au/bathrooms

SPECIFICATIONS

Recommended Use

Domestic, hotel and commercial

Colour

Chrome with white face
Chrome with satin chrome face

Pressure Rating

Suitable for high pressure applications and has 

been WELS certified to the following: 
Minimum operating pressure 150kPa
Maximum operating pressure 500kPa

Temperature Rating

Maximum continuous working temperature 70°C  

(recommended 38°C - 42°C)
Minimum 1°C

Suitable Hot Water 

Units

Storage Tank: Yes  

Continuous Flow: Yes
Gravity Feed: Not recommended

WELS

Stars: 3
Flow rate: 9L/min

Standards

AS/NZS 3662

Spray Patterns

Aurajet Spray

Disclaimer:

 Products in this specification manual must by regulation be installed by 

licensed and registered trade people. The manufacturer/distributor reserves the right to 

vary specifications or delete models from their range without prior notification. Dimensions 

are nominal measurements only.  Dimensions and set-outs listed are correct at time of 

publication however the manufacturer/distributor takes no responsibility for printing errors.  

Tech Page Version 1

Both 

Adjustable

46

56

Variable

198

216

Typical

570 - 745

800

107

AOSRCPAU

AOSRCPWHAU

page 1 of 4

The more 

stars the more 

water efficient

WATER RATING

www.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0095

Methven Australia Pty Ltd

9.0

litres per 

minute

Summary of Contents for METHVEN AURAJET AIO

Page 1: ...d 38 C 42 C Minimum 1 C Suitable Hot Water Units Storage Tank Yes Continuous Flow Yes Gravity Feed Not recommended WELS Stars 3 Flow rate 9L min Standards AS NZS 3662 Spray Patterns Aurajet Spray Disclaimer Products in this specification manual must by regulation be installed by licensed and registered trade people The manufacturer distributor reserves the right to vary specifications or delete mo...

Page 2: ...il can be oriented so that handset sits on opposite side of rail Step 5 Match the mounting brackets to wall bosses and push into place Slide rail up or down to centralise the brackets Remove the rail and tightenthe tensioning screws firmly Relocate the rail onto wall bosses and tighten grub screws top and bottom 1850mm Recommended 1000mm Rail 810 945mm 700mm Rail 510 645mm 800mm Rail 570 745mm Gru...

Page 3: ...ower performance is compromised by the build up of lime scale clean by using a soft toothbrush and gently scrubbing along the spray slot under running water Step 1 Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right Cut off the threaded nipple 13 2mm from the wall lining and apply thread seal tape to ensure a good seal Elbow Installation 13 2mm 26mm ma...

Page 4: ...on by the purchaser or any person other than a LICENSED PLUMBER Normal wear and tear Inadequate or complete lack of maintenance Chemical electrochemical or electrical influences Harsh detergents or abrasive cleaners used on product finishes 1 YEAR WARRANTY COMMERCIAL USE Commercial use is all use other than for normal domestic residential purposes including use in non business places as in public ...

Reviews: