10

2.

Press the button again to display the minimum value.

3.

Press the button a third time to resume normal operation.

Note:

 The meter will automatically exit MAX/MIN mode if no key is 

pressed within 10 seconds.

Auto Power Off

To preserve battery life, the meter is programmed to turn itself off after 5 

minutes of inactivity. The auto power off function does not apply when the 

meter is datalogging. 

Battery Replacement

When the low battery indicator appears on the LCD, the batteries must 

be replaced. 
1.

Using a Phillips head screwdriver, remove the screw on the back of

the meter.

2.

Remove the battery cover.

3.

Replace the 4 x AAA batteries.

4.

Secure the battery cover in place and tighten the screw.

Accessories and Replacement Parts 

R1110 

Test Probe Set

R1210

 Alligator Clip Set

R8888

 Medium Hard Carrying Case

Don't see your part listed here? For a complete list of all accessories and 

replacement parts visit your product page on www.reedinstruments.com.

Product Care

To keep your instrument in good working order we recommend the following:
• Store your product in a clean, dry place.
• Change the battery as needed.
• If your instrument isn't being used for a period of one month or longer

please remove the battery.

• Clean your product and accessories with biodegradable cleaner. Do not

spray the cleaner directly on the instrument. Use on external parts only.

 

REED Instruments

1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com

Summary of Contents for 800837001207

Page 1: ...AC Voltage Current Datalogger Instruction Manual R5003 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...Auto Power Off 10 Battery Replacement 10 Accessories and Replacement Parts 10 Product Care 10 Product Warranty 11 Product Disposal and Recycling 11 Product Support 11 Introduction Thank you for purch...

Page 3: ...vice center Do not operate around explosive gas vapour or dust Do not operate with any of the parts removed Do not use if the unit looks damaged Pay attention to avoid short circuits when testing a no...

Page 4: ...High and low alarms Download measurements via USB interface and analyze results with included software Magnetic back allows instrument and sensors to be secured firmly in a variety of locations Low b...

Page 5: ...nd to 24 hours Max Datapoints 256 000 Auto Shut off Yes after 5 minutes of inactivity Low Battery Indicator Yes Clamp Jaw Opening 0 5 12 7mm Power Supply 4 AAA Batteries or AC Adapter Battery Life Sam...

Page 6: ...full indicator 3 Continuous Recording 4 Maximum and Minimum Indicator 5 Memory Full Indicator 6 Battery Indicator 7 Auto Power Off Indicator 8 Normal Record Mode is selected Indicator Default 9 Selec...

Page 7: ...Button 5 Channel Input Jacks 6 USB Port 7 START STOP Button 8 Channel Selection Button 9 AC Current Clamp Jaw 10 Jaw Opening Trigger 11 Current Sensor Plug 12 Voltage Module 13 AC Voltage Probes Alli...

Page 8: ...are If your computer does not have a CD drive please visit www reedinstruments com software to download the latest R5003 software Note The Windows Installer package should be used to properly install...

Page 9: ...The REC icon will appear in the display indicating that recording has begun 7 Press and hold the START STOP button for four seconds to stop recording The REC icon will disappear from the display Note...

Page 10: ...he 4 x AAA batteries 4 Secure the battery cover in place and tighten the screw Accessories and Replacement Parts R1110 Test Probe Set R1210 Alligator Clip Set R8888 Medium Hard Carrying Case Don t see...

Page 11: ...or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when di...

Page 12: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: